manufacturer's maximum rated ambient temperature
(T
mra
).
Reduced Air Flow
: Install equipment in a rack in a
manner that does not compromise the amount of airflow
required for safe operation of equipment.
Mechanical Loading
: When mounting equipment in
rack, ensure mechanical loading is even.
Circuit Overloading
: Take into consideration the
connection of equipment to supply circuit and the effect
overloading of circuits might have on over-current
protection and supply wiring. Appropriate consideration of
equipment nameplate ratings must be given when
addressing this concern.
Reliable Grounding (Earthing)
: Maintain reliable
earthing of rack mounted equipment. Pay particular
attention to supply connections, other than direct
connections to branch circuit (for example, the use of
power strips).
4.5 Connecting Ethernet Cables
Ports on Midspan’s front panel are configured as "Pass Through" ports for
eight (1, 2, 3, 6, 4, 5, 7, 8) conductors of RJ-45 connectors. Use Category
5 cabling when making connections.
1. Connect cables from Ethernet Switch to Data In ports (lower row on
front panel).
2. Connect cables from IEEE 802.3at or IEEE 802.3af ready terminals
(PDs) to corresponding
DATA & POWER OUT
ports (upper row on front
panel).
4.6 Connecting Power Cables
When using an AC source to power Midspan, plug in the provided power
cord to back AC connector.