Microscan LVS-9585 Скачать руководство пользователя страница 25

 

LVS-9580/9585 Operating Instructions - English 

 

LVS-9580/9585 Operating Instructions - English  

Page 25 of 27 

Choose the Lighting Modes 

To choose the lighting modes: 

1. Select 

the 

Lighting

 button on the 

Grading Screen

.  

  

2.  Select the lighting mode. The default lighting modes are Red dome, White dome, and 30 degree N + S + 

E + W.   The operator may choose to add or subtract any of the lighting modes listed.  The software uses 
the selection as the new default.   

 

Grading a DPM Symbol 

To grade a DPM symbol: 

1. 

While viewing the 

Grading Screen, 

hold the verifyer trigger switch in.  The target DPM symbol then 

appears in the viewing window.  A pop-up window appears at the top of the screen which says “Hold 
trigger while searching.” 

 

Содержание LVS-9585

Страница 1: ...P N 84 9310011 02 Rev B LVS 9580 9585 Operating Instructions English LVS 9580 LVS 9585...

Страница 2: ...o the benefit of the trademark owner with no intention of infringement GS1 Solution Partner Disclaimer The information and specifications described in this manual are subject to change without notice...

Страница 3: ...5 HARDWARE OVERVIEW 6 LVS 95XX SOFTWARE STEPS 6 Log In to LVS 95XX Software 7 Turn On the LVS 9580 9585 Camera 9 Calibrate the LVS 9580 9585 10 GRADING BARCODES 13 CLEANING INSTRUCTIONS 14 ENGINEERIN...

Страница 4: ...e system For questions or concerns about the performance of the LVS 9580 9585 please contact a local Microscan Distributor or Microscan Technical Support Americas_support microscan com EMEA_support mi...

Страница 5: ...ety of surfaces including corrugated cardboard boxes shipping containers and on a static non moving web The LVS 9580 9585 grades barcodes in either picket fence or ladder orientation Picket Fence Orie...

Страница 6: ...the corners of the verifier window must be placed on the surface where the symbol is printed or marked The position of the device shown at left more closely approximates the orientation required in a...

Страница 7: ...on the LVS 9580 9585 camera Calibrating the LVS 9580 9585 Note Refer to the LVS 95XX Series Software Installation Guide for step by step instructions on installing the LVS 95XX software a hard copy v...

Страница 8: ...8 of 27 2 Click the Setup tab The Login box appears 3 Enter admin not case sensitive in the Operator ID field and in the Password field 4 Click OK LVS 95XX Software will open 5 Turn on the LVS 9580 95...

Страница 9: ...be the only camera listed in the Camera section When using the LVS 9580 9585 with the LVS 9510 5 MP both cameras appear in the Camera section Select 9580 9585 2 Select Auto Sector in the Grading Mode...

Страница 10: ...ording to industry standards The Calibrated Conformance Standard Test Card should be replaced every two years It is recommended to clean the LVS 9580 9585 window prior to calibration See the Cleaning...

Страница 11: ...e while the system is in Calibration mode 4 Place the LVS 9580 9585 window over one of the Master Grade barcodes making sure the four rubber feet surrounding the window rest firmly on a flat stable su...

Страница 12: ...f calibration fails o Re scan the Master Grade barcode and follow the above steps to calibrate It may take two or three attempts before calibration is complete o If calibration continues to fail conta...

Страница 13: ...Slowly move the LVS 9580 9585 as needed to place the green plus symbol over the center of the barcode image make sure the rubber feet rest on the substrate Then release the trigger Tip Positioning the...

Страница 14: ...window Inspect the window closely looking for any label debris that may be stuck on the window Do not scrape the window with a sharp object as this may damage the window Any damage to the window will...

Страница 15: ...selection Minimum Barcode X Dimension 1D 4 0 mils 0 10 mm 2D 5 9 mils 0 15 mm Minimum PC Requirements PC Supplied by Customer Windows 7 Pro SP1 Windows 10 Pro Intel Core i3 Processor or equivalent 4...

Страница 16: ...e EIB 4 State 4SB French CIP GS1 128 Hanxin Code HIBC Interleaved 2 of 5 ITF ITF 14 Japan Post MaxiCode MSI Plessey Pharmacode Italian Pharmacode Laetus PZN 7 and PZN 8 UPC A UPC E USPS 128 USPS Intel...

Страница 17: ...althcare Data Matrix ECC 200 EAN UPC EAN UPC and Extended Codes EAN UPC with CC GS1 DataBar Omnidirectional ITF 14 GS1 Databar 14 with CC formerly RSS 14 with CC UCC EAN with Supplementals UCC EAN 128...

Страница 18: ...evices Note The LVS 9510 does not support DPM verification DPM Verification DPM verification does not follow the same rules as traditional 1D and 2D verification Differences All dot peen symbols must...

Страница 19: ...trigger switch in The target DPM symbol then appears in the viewing window A pop up window appears at the top of the screen which says Hold trigger while searching Position the DPM symbol so that it i...

Страница 20: ...an push CTRL SHFT and software will interpret this as a trigger switch command This is useful when the optional stand is used Grading with a Shiny Surface Some direct part marks are created on a shiny...

Страница 21: ...w For most dot peen DPM symbols the cells are formed by dots and are not connected to each other This will prompt the software to enhance the image by connecting the dots However the operator must kee...

Страница 22: ...0 9585 Operating Instructions English Page 22 of 27 Reports All results measured by the software are available in a printed report These reports are also archived for future examination An image of th...

Страница 23: ...dition of 9 different lighting modes RED Dome WHITE Dome RED 30 degree N S E W RED 30 degree N S RED 30 degree E W RED 30 degree N RED 30 degree S RED 30 degree E RED 30 degree W These lighting modes...

Страница 24: ...viewing screen During calibration the Red and White box activates when that light mode is being calibrated The individual N S E and W light boxes do not activate during the calibration process Clickin...

Страница 25: ...lighting modes are Red dome White dome and 30 degree N S E W The operator may choose to add or subtract any of the lighting modes listed The software uses the selection as the new default Grading a D...

Страница 26: ...de the code until there is no motion detected Once software has found the DPM symbol the screen zooms in magnify on the symbol The software also reports what grade has been detected There is a pop up...

Страница 27: ...advises you to Release trigger 4 If the Found or Adjusting message is not shown after 20 seconds reorient the mark within the field of view and grade it again Remote Grading of a DPM Symbol To grade...

Отзывы: