background image

 

MICRONFILTER S.r.l    Corso Europa 607, 10088 Volpiano (TO)    Italy 

P.IVA 09719130016  TEL +39 011 9702 830    FAX +39 011 982 2020 

[email protected]                    www.micronfilter.it 

 

4. DIRECTIONS FOR USE AND LIMITS OF USE 

 
The filter has been designed for separating oil particles and oil emulsions from the air taken from 
machine tools such as lathes, gear cutters, grinders and cold printing machines. It is also possible to 
use it whenever there are oily mists, even in the food, pasta industries etc. on the condition that 
operating temperatures do not exceed 40°C.  

 

The filter is not designed to treat flammable or explosive vapours by nature or by reaction. For these uses, always consult the 
MICRONFILTER Technical Office. 

 

 
 
It is forbidden to smoke while the filter is operating. 

   

 

 

 
The incorrect cleaning or replacement of the filter media leads to the risk of allowing 
the polluting agent to be released into the outdoor and working environments. 
 

 

   

 

It is compulsory to earth the filter by connecting the contact points to a copper plait 
with a suitable cross section (a cross section of 2.5 mm

²

 is recommended), secured to 

the article, taking care to maintain continuity.  

 

 

Drawing 3 

 

Содержание ECOTECH

Страница 1: ... DESCRIPTION OF THE FUNCTIONS 2 3 PRELIMINARY INSPECTION AND ASSEMBLY 4 3 1 Assembling the cartridge 4 4 DIRECTIONS FOR USE AND LIMITS OF USE 6 5 TECHNICAL DATA 8 5 1 Cartridge filter 11 6 INSTALLATION 14 7 ADJUSTMENTS 14 7 1 System 14 8 MAINTENANCE 14 8 1 Oil discharge 16 9 ELECTRICAL CIRCUIT DIAGRAMS 18 10 MARKING AND CERTIFICATION 19 11 SYMBOLS 19 12 TROUBLESHOOTING 21 13 WARRANTY 22 ...

Страница 2: ...gal aspirator casing It passes through the vertical duct where mechanical separation of the particles suspended in the air takes place because of the centrifugal effect due to the rotation of the air imparted by the helical element The oil particles separated in this way come together on the wall of the pipe held back by a wire mesh They drip into the collection hopper 2 and from here to the remov...

Страница 3: ...3 MICRONFILTER S r l Corso Europa 607 10088 Volpiano TO Italy P IVA 09719130016 TEL 39 011 9702 830 FAX 39 011 982 2020 info micronfilter it www micronfilter it ...

Страница 4: ...er removing the material from the packaging make a visual check that it has not been damaged during transportation and use the checklist to check that all the components have been supplied If this is not the case inform your dealer as soon as possible and nevertheless no later than 10 days from delivery For movement over short distances in the workplace it is necessary to disconnect the source of ...

Страница 5: ...702 830 FAX 39 011 982 2020 info micronfilter it www micronfilter it This operation must be carried out carefully in order to prevent any leakage For a clearer picture of assembly see Drawings 2 and 3 Drawing 2 The cartridge is fixed to the platform by pressure exerted by the support plate A B ...

Страница 6: ...L 39 011 9702 830 FAX 39 011 982 2020 info micronfilter it www micronfilter it after placing the cartridge on the plate rotate it clockwise positioning the seal of the cartridge a few millimetres from the roof Using the box spanner supplied turn the bolt clockwise until fully blocked ...

Страница 7: ...s etc on the condition that operating temperatures do not exceed 40 C The filter is not designed to treat flammable or explosive vapours by nature or by reaction For these uses always consult the MICRONFILTER Technical Office It is forbidden to smoke while the filter is operating The incorrect cleaning or replacement of the filter media leads to the risk of allowing the polluting agent to be relea...

Страница 8: ...ronfilter it Any act which compromises the functionality integrity and or safety of the machine structure the internal equipment both electrical and mechanical and any control and connection component is considered improper use The MICRONFILTER Technical Office is always available for any further information about using the product 5 TECHNICAL DATA ...

Страница 9: ...9 MICRONFILTER S r l Corso Europa 607 10088 Volpiano TO Italy P IVA 09719130016 TEL 39 011 9702 830 FAX 39 011 982 2020 info micronfilter it www micronfilter it ...

Страница 10: ...10 MICRONFILTER S r l Corso Europa 607 10088 Volpiano TO Italy P IVA 09719130016 TEL 39 011 9702 830 FAX 39 011 982 2020 info micronfilter it www micronfilter it ...

Страница 11: ...11 MICRONFILTER S r l Corso Europa 607 10088 Volpiano TO Italy P IVA 09719130016 TEL 39 011 9702 830 FAX 39 011 982 2020 info micronfilter it www micronfilter it 5 1 Cartridge filter ...

Страница 12: ...12 MICRONFILTER S r l Corso Europa 607 10088 Volpiano TO Italy P IVA 09719130016 TEL 39 011 9702 830 FAX 39 011 982 2020 info micronfilter it www micronfilter it ...

Страница 13: ...13 MICRONFILTER S r l Corso Europa 607 10088 Volpiano TO Italy P IVA 09719130016 TEL 39 011 9702 830 FAX 39 011 982 2020 info micronfilter it www micronfilter it ...

Страница 14: ...rom infiltrations of rain 7 ADJUSTMENTS 7 1 System To adjust the unit flow rate intervene on the throttle shutter optional mounted on the raceways using the respective knob The opportunity to adjust the flow rate allows better execution of the work ensuring a longer working life for the various filtering baffles and less power absorption by the fan with consequent energy saving 8 MAINTENANCE Do no...

Страница 15: ...tion hatch replace the cartridge if abrasions and or breakages are evident Check the state of the coalescing pre filter that surrounds the cartridge Drain the PVC oil collection container periodically Periodically check that the fan does not show signs of anomalous vibrations The frequency of inspections cannot be pre determined as it is influenced by factors which cannot be estimated beforehand s...

Страница 16: ...w micronfilter it 8 1 Oil discharge It is possible to access the PVC oil collection container by opening the inspection hatch A The bottom of the container B is screwed to the collection hopper Unscrew the PVC in an anti clockwise direction Pay special attention while screwing on the container The thread could cause leaks if fitted incorrectly ...

Страница 17: ...ipped with personal protective equipment protective masks gloves and fully respecting the accident prevention regulations in the country of use NOTE the term qualified personnel refers to personnel that have followed specialist courses and training and have experience in installing putting into service and maintaining the systems Dispose of the used filters carefully sending them to specialised di...

Страница 18: ...aly P IVA 09719130016 TEL 39 011 9702 830 FAX 39 011 982 2020 info micronfilter it www micronfilter it 9 ELECTRICAL CIRCUIT DIAGRAMS During electrical connection respect the voltage correct polarity and direction or rotation WIRING DIAGRAM WITH CIRCUIT BREAKER ...

Страница 19: ...amended Its suitability is shown by the application of the CE marking on the machine and the declaration of conformity which accompanies this manual 11 SYMBOLS These symbols together with the relative wording indicate the potential risk resulting from disregarding the provisions with which they have been combined as specified below Sticker indicating that live parts at 400V are present on the cont...

Страница 20: ... TEL 39 011 9702 830 FAX 39 011 982 2020 info micronfilter it www micronfilter it Stickers indicating that it is compulsory to wear gloves while performing maintenance on the filters Stickers indicating that it is compulsory to wear masks while performing maintenance on the filters ...

Страница 21: ...ter effect Check that the filters are clean and remove and replace them if necessary 2 Reduction of the air flow intake Dirty filters Check that the filters are clean and remove and replace them if necessary 3 The fan vibrates The wheel is off balance Remove and clean the fan wheel 4 The fan rotates but there is insufficient aspiration The direction of rotation is incorrect Invert the two connecti...

Страница 22: ...upplier the product deemed non conforming and or allow people assigned by the Supplier to carry out all the checks that the Supplier deems suitable in order to ascertain the effective non conformity or defect of the product The lack of communication of the potential non conformity or fault of the product in the times indicated and or if the latter is not made available shall cause the immediate te...

Страница 23: ...arantee shall terminate if the product is tampered with modified repaired by service centres other than that of the Supplier and by personnel not directly employed or authorized by the Supplier himself and or in the case of the use of non original components or consumables filters seals etc The Supplier does not guarantee the inexistence of claims or rights based on industrial or intellectual prop...