An internal bay is provided for drives that are 3.5 inches wide and either 1 inch or 1.6 inches high. The
possible combinations (height and quantity) are as follows:
•
Up to a total of six drives, each 1 inch high
•
Up to a total of three drives, each 1.6 inches high
•
Up to a total of four drives, two that are 1.6 inches high plus two that are 1 inch high
The side cover provides easy access to drives in the internal bay. The bay swings out and can be
removed.
Drives can consume up to 11 watts of power. Drives must be specified to run at a maximum ambient
temperature of 50
°
C.
The system was designed to allow the user to install a Redundant Array of Independent Disks (RAID). A
software implementation with onboard SCSI or an add-in board can be used to set up RAID applications.
([WHUQDO%D\VIRULQFK5HPRYDEOH0HGLD'HYLFHV
The chassis has three 5.25-inch half-height bays that are accessible from the front of the system. These
bays are intended to provide space for tape backup or other removable devices. As shipped, a CD-ROM
drive may be installed in the top of the three bays.
You can convert the 5.25-inch bays to a single full-height bay. We recommend that you do not use these
bays for hard disk drives, because they generate EMI, ESD susceptibility increases, and the drive will not
be adequately cooled.
3RZHU6XSSO\
Your chassis includes either a 300 watt or a 275 watt power supply
:DWW3RZHU6XSSO\
The 300 watt universal-type power supply is designed to minimize EMI and RFI. The supply operates
within the following voltage ranges and is rated as follows:
•
100-120
V
∼
at 50/60 Hertz (Hz); 4.6 A maximum
•
200-240
V
∼
at 50/60 Hz; 2.3 A maximum
The DC output voltages of the power supply are +5 V, +12 V, +3.3 V, -5 V, -12 V, and +5 V standby.
Power to the server board is provided through the power cable to the 24-pin main power connector. The
Auxiliary power connector provides the interface to the IMB bus and sensing signals for the Baseboard
Management Controller on the server board. Through this interface, LANDesk® Server Manager can
monitor the power supply.
6\VWHP&RROLQJ
The chassis includes two fans for cooling and airflow. One of these is the integrated fan in the power
supply. Additional fans are integrated with each processor to provide additional cooling and airflow.