Form No. 008-42104-00

Rev. 12/95

WARRANTY

MICROMERITICS INSTRUMENT CORPORATION warrants for one year from the date of shipment each
instrument it manufactures to be free from defects in material and workmanship impairing its usefulness under
normal use and service conditions except as noted herein.

Our liability under this warranty is limited to repair, servicing and adjustment, free of charge at our plant, of any
instrument or defective parts when returned prepaid to us and which our examination discloses to have been
defective. The purchaser is responsible for all transportation charges involving the shipment of materials for war-
ranty repairs. Failure of any instrument or product due to operator error, improper installation, unauthorized
repair or alteration, failure of utilities, or environmental contamination will not constitute a warranty claim. The
materials of construction used in MICROMERITICS instruments and other products were chosen after extensive
testing and experience for their reliability and durability. However, these materials cannot be totally guaranteed
against wear and/or decomposition by chemical action (corrosion) as a result of normal use.

Repair parts are warranted to be free from defects in material and workmanship for 90 days from the date of
shipment.

No instrument or product shall be returned to MICROMERITICS prior to notification of alleged defect and
authorization to return the instrument or product. All repairs or replacements are made subject to factory inspec-
tion of returned parts.

MICROMERITICS shall be released from all obligations under its warranty in the event repairs or modifications
are made by persons other than its own authorized service personnel unless such work is authorized in writing by
MICROMERITICS.

The obligations of this warranty will be limited under the following conditions:

1.

Certain products sold by MICROMERITICS are the products of reputable manufacturers, sold under their
respective brand names or trade names. We, therefore, make no express or implied warranty as to such prod-
ucts. We shall use our best efforts to obtain from the manufacturer, in accordance with his customary prac-
tice, the repair or replacement of such of his products that may prove defective in workmanship or materials.
Service charges made by such manufacturer are the responsibility of the ultimate purchaser. This states our
entire liability in respect to such products, except as an authorized person of MICROMERITICS may other-
wise agree to in writing.

2.

If an instrument or product is found defective during the warranty period, replacement parts may, at the dis-
cretion of MICROMERITICS, be sent to be installed by the purchaser, e.g., printed circuit boards, check
valves, seals, etc.

3.

Expendable items, e.g., sample tubes, detector source lamps, indicator lamps, fuses, valve plugs (rotor) and
stems, seals and O-rings, ferrules, etc., are excluded from this warranty except for manufacturing defects.
Such items which perform satisfactorily during the first 45 days after the date of shipment are assumed to be
free of manufacturing defects.

Purchaser agrees to hold MICROMERITICS harmless from any patent infringement action brought against
MICROMERITICS if, at the request of the purchaser, MICROMERITICS modifies a standard product or manu-
factures a special product to the purchaser’s specifications.

MICROMERITICS shall not be liable for consequential or other type damages resulting from the use of any of
its products other than the liability stated above. This warranty is in lieu of all other warranties, express or
implied, including, but not limited to, the implied warranties of merchantability or fitness for use.

4356 Communications Drive

         

 

Norcross, GA 30093-1877

 

  

 

Fax (770) 662-3696

Domestic Sales - (770) 662-3633

                                           Domestic Repair Service - (770) 662-3666

International Sales - (770) 662-3660

                    

                          Customer Service - (770) 662-3636

Содержание AquaPrep 055

Страница 1: ...AquaPrepTM 055 Operator s Manual 055 42801 01 October 2009...

Страница 2: ...Micromeritics and Saturn DigiSizer are trademarks of Micromeritics Instrument Corporation Teflon is a registered trademark of Norton Company Micromeritics Instrument Corporation 2002 2009 All rights...

Страница 3: ...e following conditions 1 Certain products sold by MICROMERITICS are the products of reputable manufacturers sold under their respective brand names or trade names We therefore make no express or impli...

Страница 4: ......

Страница 5: ...Description 1 3 Specifications 1 4 2 INSTALLATION Unpacking and Inspecting the Equipment 2 1 Equipment Damage or Loss During Shipment 2 1 Equipment Return 2 1 Installing the AquaPrep 2 2 Selecting the...

Страница 6: ......

Страница 7: ...uaPrep safety precautions and specifications Chapter 2 INSTALLATION Describes how to unpack inspect and install the AquaPrep Chapter 3 OPERATION Provides instructions for operating the AquaPrep Chapte...

Страница 8: ...sis Tap water varies greatly in its dissolved air content and the presence of debris This water must be deionized and well filtered before using with the AquaPrep Filtering the water through at least...

Страница 9: ...and outlet connectors on its front panel The switch for turning it on and off is located on the rear panel just left of the power card entrance Figure 1 1 The AquaPrep 055 The air removed from the wat...

Страница 10: ...Accommodates to standard power mains worldwide Voltage 100 120 220 240 VAC 10 Current 2 0 A 100 120 VAC 1 0 A 220 240 VAC Frequency 50 60 Hz Water Filtered and deionized EXPOSED MATERIALS Polypropyle...

Страница 11: ...rrier of the equipment immediately Equipment Return Micromeritics strives to ensure that all items arrive safely and in working order Occasionally due to circumstances beyond our control equipment is...

Страница 12: ...truments leave the factory set for 120 VAC and with the line fuse removed The correct setting of the universal power entrance must be checked and the appropriate fuse installed before the AquaPrep can...

Страница 13: ...t out of the power connector housing 4 Orient the voltage selector card so that the desired voltage is indicated at the bottom Orient the indicator pin so that it points upward as shown in the followi...

Страница 14: ...e side with the double fuse slots is away from the cover b If the fuse block is positioned properly for the desired fusing proceed to Step c If the fuse block is not positioned properly 1 Remove the f...

Страница 15: ...put power connector and snap it into place Once the fuse block and cover assembly are in place the position of the indicator pin shows the input power selected The fuses used in the AquaPrep must be i...

Страница 16: ...t panel Connecting the Power Cord Insert one end of the power cord into the input power connector on the rear panel of the Aqua Prep and the other end into an appropriate power source Do not turn the...

Страница 17: ...m or 2 in the surface of the water so that splashing does not re introduce air into the liquid It is important that the tubing is arranged at different levels This promotes circulation and ensures tha...

Страница 18: ...dequacy of deaeration For example you may observe 20 bubbles per minute If the background measurement you will perform next shows adequate deaeration you can watch for approximately 20 bubbles per min...

Страница 19: ...for ordering information Hydrophobic Capsule Replace the hydrophobic capsule when excessive deterioration is detected Refer to Chapter 5 for ordering information 1 Unplug the AquaPrep from its power...

Страница 20: ......

Страница 21: ...ccessories can be ordered by telephone 770 662 3636 email customerservice micromeritics com internet www micromeritics com Part Number Item and Description 003 51130 01 Fuse 1 0 Amp 5 x 20 mm slow blo...

Страница 22: ......