2.3 Configuration
Prior to establishing a wireless link, each MHX-900 module that will
participate in the link must be correctly configured for compatibility and for
the desired mode of operation.
The two most common types of networks used are:
n
Point-to-point
: A
Master
station communicates with a single
Slave
station.
n
Point-to-multipoint
: A
Master
station communications with
two or more
Slave
stations.
Within any network, the Master will communicate only with Slave(s)
assigned to the same network. Similarly, a Slave will only communicate with
the Master of the network to which it is assigned.
2.3.1 Quick Start Approach
The minimum configuration requirements for point-to-point and point-to-
multipoint are summarized below.
These requirements will get you started
and only ensure that a link can be established, but do not necessarily provide
the best performance
; optimization of the communications link is discussed
in later sections.
A. Point-to-Point
To establish a point-to-point communications link, the following requisites
must be satisfied:
n
The
Operating Mode
for one modem must be configured as a
“
Master - Point-to-Point
”, and the other as a “
Slave - Point-to-
Point
”.
n
The
Wireless Link Rate
for both modems must be the same.
n
The
Network Address
assigned for both modems must be the
same.
n
The
Unit Address
assigned for both modems must be the same.
n
The same
Hopping Pattern
must be selected for both modems.
n
The same
Hopping Interval
must be selected for both modems.
n
Both modems must use the same
Encryption Key
.
Содержание MHX-900
Страница 2: ......
Страница 4: ......
Страница 24: ...20 MHX 900 Operating Manual Appendix A Modem Command Summary...
Страница 26: ...22 MHX 900 Operating Manual Appendix B Serial Interface...
Страница 28: ...24 MHX 900 Operating Manual Appendix C Sample Schematic Diagram...
Страница 30: ...26 MHX 900 Operating Manual Appendix D Modem Setup Overview...
Страница 32: ...28 MHX 900 Operating Manual Appendix E Technical Specifications...