MHX-900 Operating Manual: Chapter 2 Initial Setup and Configuration
Warning:
Using an antenna that
is inappropriate for use with the
MHX-900 module could result in
undesired performance, and may
damage the unit. It is the user’s
responsibility to ensure the
antenna has adequate lightning
protection.
B. Point-to-Multipoint
To establish a point-to-multipoint network, the following requisites must be
satisfied:
n
The
Operating Mode
for one modem must be configured as a
Point-to-Multipoint Master
, and the others as
Point-to-
Multipoint Slave
s.
n
The
Wireless Link Rate
for all modems must be the same.
n
The
Network Address
assigned to all modems must be the same.
n
Each Slave must be assigned a unique
Unit Address
(Unit Address
0 is not supported).
n
The same
Hopping Pattern
must be selected for all modems.
n
The
Hopping Interval
is determined by the Master modem, and is
therefore configured only at the Master.
n
All modems must use the same
Encryption Key
.
Each of the parameters above are defined by specific S registers. Settings are
not immediately stored in non-volatile memory. The command &W writes
the current configuration into non-volatile memory, and are therefore retained
even after powering down. Each item and the settable parameters within the
modem configuration are described in detail in Chapter 3: Configuration
Options.
2.4 Checking the Link
Once configured properly, a pair or set of communicating modems can be tested
to ensure that a link can be successfully established. Connect an appropriate
antenna to each MHX-900 module.
The modems should indicate the status of
the wireless link via the RSSI outputs on each unit:
If the link is good, up to three RSSI outputs should be active; and if the link
is absent (due to a fault at one end or another, such as misconfiguration), the
outputs will be inactive.
It is recommended that if MHX-900 modules will be deployed in a field
where large distances separate the units, the modems should be configured
and tested in close proximity (
e.g.
, in the same room) first to ensure a good
link can be established and settings are correct. This will facilitate
troubleshooting, should problems arise. In a multipoint system, only the
Slave modems give valid RSSI readings.
Microhard Systems Inc. provides a development system which supplies all
system power and RS-232 level shifting circuits required to connect a MHX-
900 module to a PC. This can serve as an invaluable aid in OEM system
design.
Содержание MHX-900
Страница 2: ......
Страница 4: ......
Страница 24: ...20 MHX 900 Operating Manual Appendix A Modem Command Summary...
Страница 26: ...22 MHX 900 Operating Manual Appendix B Serial Interface...
Страница 28: ...24 MHX 900 Operating Manual Appendix C Sample Schematic Diagram...
Страница 30: ...26 MHX 900 Operating Manual Appendix D Modem Setup Overview...
Страница 32: ...28 MHX 900 Operating Manual Appendix E Technical Specifications...