MHX-900 Operating Manual: Appendix E Technical Specifications
27
E. Technical Specifications
Electrical/Physical
Data Interface
Asynchronous Serial Port, TTL Levels
RS-232 Signals
Sig. Gnd, TX, RX, DCD, DSR, DTR, RTS, CTS
Other Signals
Reset, RxMode, TxMode, RSSI1, RSSI2, RSSI3
(All except Reset are status signals)
User Interface
AT Command line interface
Bandwidth / Data Rate
2,400 - 115,200 bps, uncompressed half-duplex,
Approx. 100 kbps sustained in intelligent asymmetrical full-duplex
transmission mode
Communications Range
Up to 30 kilometres (19 miles) line of sight
Power Requirements
4.75 to 5.5 VDC
Power Consumption
5500 mA at 1 W transmit, 220 mA receive
Operating Frequency
902 - 928 MHz
System Gain
135 dB
Sensitivity
-105 dBm
Output Power
1mW, 10mW, 100mW, 1W (user-selectable)
Spreading Code
Frequency Hopping
Hopping Patterns
20 pseudo-random, user-selectable
Error Detection
CRC-16 with auto re-transmit
Dimensions (WxDxH)
Encl: 2.1” x 3.5” x 0.75” (53 mm x 89 mm x 19 mm)
Weight
75 grams
Operating Environment
Temperature: -40 to +65°C
Humidity: 5 to 95%, non-condensing