background image

22 

- Lamp off via DMX 

This function allows you to switch off the lamp by DMX. Use the 

[Up] 

and 

[Down] 

keys to select 

"On" 

if you 

want to switch off the lamp by DMX or 

"Off" 

if you don’t want to switch off the lamp by DMX and press 

[Enter] 

to confirm or 

[Mode] 

to cancel and return to the menu

- Temperature 

Inside temperature readouts of the fixture in Celsius. Inside temperatures below 66° C are not critical. 66° C and 
more lead to the lamp being switched off. Please note that the outside temperature should not exceed 40° C. 

- Fan speed operating 

By using this function you can choose 4 types of fan speed operating. Browse through this menu by the pressing 

[Up] 

and 

[Down] 

keys - the display shows step by step the following messages: 

"HIGH, reG, Lo.HI, Lo.OF

". 

Press 

[Enter] 

if you wish to select one of them or 

[Mode] 

to cancel and return to the menu. 

- high speed of the fans 

The cooling fans work on max. speed (max. cooling). 

- continuous controlling of the fan speed 

The fan automatically raises its speed in order to control inside 
temperature of the lighting, if the temperature inside increases 
about certain level (the low fan speed reduces the cooling of the 
lighting). This cycle can repeat several times until the temperature 
inside is on a suitable level. 

low /high speed of the fan operating 

The fan keeps the adjusted low speed until the temperature exceeds max. inside temp. of the fixture, then the 

ULTRA SPOT 

automatically switches from low to high fan-speed. 

- low speed / switch off the lamp operating 

The fan keeps the adjusted low speed until the temperature exceeds max. inside temp. then the 

ULTRA SPOT 

automatically switches off the lamp

 
- Default settings 

Press 

[Enter] 

to reset all fixture personalities (not the 

adjusting functions) to the default values. On the display 
will appear,

 “rSt” 

meaning that the fixture makes the 

reset. See the table of personality setting and their de-
fault positions. 
 

 

ENGLISH

 

 

2. SAFETY 

 

2.1 Safety instructions 

 

 

 

This device has left our premises in absolutely perfect condition. In order to maintain this 
condition and to ensure a safe operation, it is absolutely necessary for the user to follow 
the safety instructions and warning notes written in this user manual. 
 

Important: 

Damages caused by the disregard of this user manual are not subject  
to warranty.  
The dealer will not accept liability for any resulting defects or problems. 

 

If the device has been exposed to drastic temperature fluctuation (e.g. after transportation), 
do not switch it on immediately. The arising condensation water might damage your device. 
Leave the device switched off until it has reached room temperature. 
This device falls under protection-class I. The power plug must only be plugged into a pro-
tection class I outlet. 
Never let the power-cord come into contact with other cables! Handle the power-cord and 
all connections to the power supply with particular caution! 
Make sure that the available voltage is not higher than stated on the rear panel. 
Make sure that the power-cord is never crimped or damaged by sharp edges. Check the 
device and the power-cord from time to time. 
Always disconnect from the power supply, when the device is not in use or before cleaning 
it. Only handle the power-cord by the plug. Never pull out the plug by tugging the power-
cord. 
During the initial start-up some smoke or smell may arise. This is a normal process and 
does not necessarily mean that the device is defective. 

Caution: 

During the operation, the housing becomes very hot. 

 
Do not switch the device on and off in short intervals as this would reduce the lamp’s life. 

 

Please consider that damages caused by manual modifications to the device are not sub-
ject to warranty.  
 
Keep away children and amateurs! 

CAUTION !  

Be careful with your operations. 

With a dangerous voltage you can suffer a  

dangerous electric shock when touching the wires!

 

HEALTH HAZARD! 

Never look directly into the light source, as sensitive persons 

may suffer an epileptic shock (especially meant for epileptics)!

 

Содержание ARENA ultra spot

Страница 1: ...amaged it has to be replaced by authorized dealers only in order to avoid hazards Should you have further questions please contact your dealer We hope you will enjoy your MICROH ARENA ULTRA SPOT We ca...

Страница 2: ...tructions depending on the installation spot and usage have to be adhered by a skilled installer and any safety problems have to be re moved DANGER TO LIFE Disconnect from power supply before starting...

Страница 3: ...of base including handles 470 mm Width of yoke 450 mm Height head horizontal 580 mm Weight net 33 kg Shipping weight 38 kg 3 ENGLISH Table of Contents 1 Introduction Features 4 Description of the fixt...

Страница 4: ...it Pan Tilt movement resolution Pan movement range 530 Tilt movement range 280 8 16 bit movement resolution Automatic Pan Tilt position correction High luminous efficiency parabolic mirror and double...

Страница 5: ...fixture if the magnetic indexing circuit malfunctions sensor failed or magnet missing or the stepping motor is defective or its driver circuit on the main PCB The gobo wheel is not located in the def...

Страница 6: ...nd to make a reset in order to check the newly adjusted positions of the colour gobo and effect wheels When the reset of the fixture is finished the display will show the FCAL message Press Enter to r...

Страница 7: ...ENGLISH 2 SAFETY 2 1 Safety instructions This device has left our premises in absolutely perfect condition In order to maintain this condition and to ensure a safe operation it is absolutely necessar...

Страница 8: ...r switching on the fixture Use the Up and Down keys to select On if you wish to switch on the lamp automatically after switching on the fixture or Off if you wish the lamp off after switching on the f...

Страница 9: ...ng Enter Manual control of effects This function allows you to control manually the channel functions of the fixture Use the Up and Down keys to select desired function and press Enter to adjust the e...

Страница 10: ...or strobe effects 1 10 flashes per second 6 11 Fan The ARENA ULTRA SPOT is cooled by three axial fans one each in the projector head and one in the base The speed of the fan and of course the noise ca...

Страница 11: ...yellow green cyan blue UV 6 4 Static gobo wheel This wheel has 9 metal gobos open position all gobos are interchangeable The gobos have an outside diameter of 27 mm and an image diameter of 23 mm Gobo...

Страница 12: ...re address which is defined as the first channel from which the ULTRA SPOT will respond to the controller If you set for example the address to channel 5 the ULTRA SPOT will use the channel 5 to 20 fo...

Страница 13: ...e fixture or one fixture with another Occupation of the XLR connection If you are using the recommended MICROH ARENA ULTRA SPOT controllers you can con nect the DMX output of the controller directly w...

Страница 14: ...f the slider to the other 0 255 128 center The head can be turned by 280 and stopped at any position you wish Channel 3 Pan fine 16 bit Channel 4 Tilt fine 16 bit Channel 5 Speed of PAN TILT movement...

Отзывы: