background image

Microframe Corporation

Series 3002 - DataPage II Transmitter w/Line Port

11

3  SYSTEM OVERVIEW

3.1 PERFORMANCE

The system will normally cover 95% of all

range requirements with the use of just the
internal antenna.  The helical quarter wave
antenna supplied with the system can provide
ranges of up to half a mile free space and will
normally cover industrial buildings of up to
100,000 square feet or more.  This short helical
wound antenna can be replaced with a dipole
antenna, which can provide ranges in excess of
one mile in free space and considerably en-
hance the unit’s performance in industrial or
commercial environments. Position the unit on
the opposite end of the desk to computers,
telephones and intercoms, etc. to minimize the
potential for cross interference.

3.2 RANGE EXPANSION

The range and performance of this equip-

ment can be improved by the addition of more
efficient aerials.* These can be installed either
inside or outside the building and are connected
to the transmitter with 50-ohm coaxial cable.
An amplifier is also available for very large
sites.* Consult your dealer for further details.

A glass mount is available to install on the

inside of a suitable window, which can boost
range, especially if it’s required in one direction
from the building.

The center fed half wave dipole measuring

approximately 300 mm from tip to tip will
provide excellent all around local signaling.
This can be mounted either inside or outside
the building and is available in either a light-
weight or heavy-duty stainless steel design.

Collinear aerials are also available for exter-

nal application and will, when elevated, boost
overall range with a slight loss to some local
signals.

Pre-terminated coaxial feeders are avail-

able for 5-, 10- or 15-meter requirements.  High
frequencies can equate to high power losses.
Always use the best quality cable.  RG58 is only
acceptable on cable runs of up to 5 meters.  We
recommend RG213 or equivalent on greater
lengths.  If in doubt consult your dealer.  Co-
axial cable intended for TV satellite or CCTV
installations is normally 75 ohm, and therefore
totally unsuitable, and can cause severe trans-
mitter damage.

*Subject to license conditions.

> Never install aerials near overhead power

lines or adjacent to telephone or public address
or data communication lines.

>Avoid, wherever possible, running aerial

feeder cables alongside other cables, e.g.:  tele-
phone and mains.

3.3 FACTORY PROGRAMMING

When the system leaves the factory, it will

have been programmed with a default configu-
ration that sets up the system as follows:

Number of pagers: RANGES SET AS

ORDERED

Default bleep type: A
Password:

72765

System Identity:

REFER TO ORDER
DOCUMENTATION

The system parameters can be changed and

re-programmed via the keyboard, if required
(see previous section: Program Parameters, 3:
Phone).

Your system has been programmed to be

fully functional before leaving the factory.  There
is no need to change any settings if you are
happy with the factory settings.

3.4 OVERVIEW

IMPORTANT! This unit must not under

any circumstances be connected direct to
the public telephone network. It is only
intended for indirect connection to an in-
house telephone exchange. Any attempt to
operate the unit other than as intended
will invalidate all equipment warranties
and may result in damage to the equip-
ment, the telephone network or both.

The Scope Digital Paging Interface can be

used to transmit numeric messages from any
telephone connected to your exchange, direct
to the pocket of the individual being paged.
There are two types of interface available that
cover all types of hybrid and PBX systems with
DTMF capability. These can be supplied in two
basic configurations.

  1) LP. This interface connects to an exter-

Содержание SERIES 3002

Страница 1: ...Microframe Corporation Series 3002 DataPage II w Line Port Interface Operating Manual B3002 7011 B3002 7011 ...

Страница 2: ......

Страница 3: ...STALLATION SPECIFICATION GUIDE ITEM NO A3002 7011 REVISION DATE 04 02 Microframe Corporation 604 S 12th Street Broken Arrow OK 74012 Tel 918 258 4839 Toll Free 1 800 635 3811 Website www microframecorp com E mail support microframecorp com ...

Страница 4: ...or warranty service please contact Microframe at 1 800 635 3811 A tech will gladly assist you Assistance For any product assistance or maintenance help contactMicroframebyeithercalling1 800 635 3811or emailing us at support microframecorp com Safety Do not install substitute parts or perform any modi fication to the product without first contacting Microframe Warning All power transformers line co...

Страница 5: ...HA MESSAGE 9 2 6 PAGER TURN OFF FROM BASE 9 2 7 TURNING OFF ALL PAGERS 9 2 8 INDIVIDUAL PAGER TURN OFF 9 2 9 ADVANCED FEATURES 9 2 10 SPEED DIALING 10 2 11 TONE ONLY PAGING 10 3 SYSTEM OVERVIEW 11 3 1 PERFORMANCE 11 3 2 RANGE EXPANSION 11 3 3 FACTORY PROGRAMMING 11 3 4 OVERVIEW 11 4 GEO PULSAR USER GUIDE 13 4 1 TURNING ON THE PAGER 13 4 2 SENDING A NUMERIC MESSAGE 13 4 3 RECEIVING A PAGE 13 4 4 SE...

Страница 6: ...ager Microframe can pro grampre definedalphamessagestoenhancecommuni cation between the sender and receiver Up to 874 total charactersmaybeused makingitpossibletoprogramas manydifferentmessagesasyouwantwithinthatcharac ter limit Every space counts as a character as does every line For example you could pre define 45 mes sages that are 2 5 words in length or 70 two word messages Allpre definedmessa...

Страница 7: ...d mounting the transmitter in the im mediate vicinity of telephones exchanges or computer equipment A few feet can make the 1 1 CONNECTING THE ANTENNA Connect the 90 degree aerial to the BNC connector bayonet twist lock located at the side of the transmitter Slide the plastic cover over the connector engaging the two lugs into the corresponding recesses in the side of the case Thiswillmaintainthea...

Страница 8: ...re thoughtpriortoinstallation coupledwithafewtests can normally avoid most problems 1 5 DRY CONTACTS There are two volt free dry contacts available for use with either Normally Open Normally Closed or Change of State switches When either is triggered the pro grammedmessage s willbesenttotheselectedpager or group of pagers When used in the Normally Open mode only themessagewillrepeatwhileintheactiv...

Страница 9: ...thin the pager itself From a phone within your PBX system dial the extension or line port that the DataPage II is attached to You will hear a three tone sign 2 OPERATION on threenotesescalatinglowtohigh Dialthe pager number then press or see note Wait for acceptance tone single mid tone or pro ceed To send one of the pre defined messages from the table supplied dial followed by the message number ...

Страница 10: ...past the inactivity timer which effectively means that the sign on tones will never be received 2 10SPEEDDIALING It may be possible to effect some speed dial functions with your telephone system however telephone ex changes vary as to the way in which they perform dependingupontheirowninternalprotocol Withcertain systems you may have to establish an audio connection with the port prior to sending ...

Страница 11: ...irements High frequencies can equate to high power losses Always use the best quality cable RG58 is only acceptable on cable runs of up to 5 meters We recommend RG213 or equivalent on greater lengths If in doubt consult your dealer Co axial cable intended for TV satellite or CCTV installationsisnormally75ohm andtherefore totally unsuitable and can cause severe trans mitter damage Subject to licens...

Страница 12: ...F This interface is only intended for use with systems dedicated to two wire ports Access is gained by dialing the extension number The ringing will alert the DataPagewhichwillpickuptheline Useofthisinterface with hybrids of any sort is not recommended and we cannot provide any support for such applications Both of these interfaces contain line voltage isolation devices There is total electrical i...

Страница 13: ...NDING A GROUP CALL PAGE All pagers respond to call number 900 unless another group call number has been chosen To page all pagers at once simply enter 900 and SEND 4 5 MANUAL PAGER TURN OFF Pressthe RIGHTARROWBUTTON The words PGR OFF will appear on the LCD screen Press the LARGE BLACK BUTTON once to confirm NOTE If you have chosen to disablethepagers on offbutton thepagerscan only be turned off fr...