![MicroControl uCAN.8.dio-BOX Скачать руководство пользователя страница 48](http://html1.mh-extra.com/html/microcontrol/ucan-8-dio-box/ucan-8-dio-box_manual_1786185048.webp)
Object Dictionary
CANopen Protocol
μCAN.8.dio-BOX
MicroControl Version 2.00
Page
48
8
Manufacturer Device Name
Index 1008
The object at index 1008h contains the manufacturer device na-
me.
Sub-Index
Data Type
Acc.
Name
Default Value
0
Visible String
ro
Device name
μCAN.8.dio
The object is read-only. Only sub-index 0 is supported. An access
to other sub-indices will lead to an error message.
Manufacturer Hardware Version
Index 1009h
The object at index 1009h contains the manufacturer hardware
version.
Sub-Index
Data Type
Acc.
Name
Default Value
0
Visible String
ro
Hardware version
HW-1.1
The object is read-only. Only sub-index 0 is supported. An access
to other sub-indices will lead to an error message.
Manufaturer Software Version
Index 100Ah
The object at index 100Ah contains the manufacturer software
version.
Sub-Index
Data Type
Acc.
Name
Default Value
0
Visible String
ro
Software version
SW-1.0
The object is read-only. Only sub-index 0 is supported. An access
to other sub-indices will lead to an error message.