Chapter 5
Printer Commands
428T Operator’s Manual - 880037-0140 5-21
d) The ^Ax^D125 command controls the location of the euro character
as provided in the model 48-466 printers. The euro character which
by default is mapped to location 0xE3 (227 decimal) can be moved
to another location specified by the x if x>0. If x=0 no remapping will
take place and the euro will stay at location 0xE3. Also if the printer
must be configured to use a code page other than the default (0000)
code page.
The 48-466 and X24 code bases are not fully compatible, so the
emulation does have some limitations. The known limitations are briefly
mentioned below:
a) The 48-466 data stream should not use an Attribute Number of 2
(fixed/non-proportional) which is the seventeenth parameter. It is
not technically possible to emulate this model 48-466 feature.
b) The CS value used in conjunction with the AN set to a 2 to produce
a negative kerning effect should be removed and the field defaulted.
This is the 11
th
field defined in the format lines.
c) Fields that were using an AN of 2 and CS for negative kerning may
require that their placement coordinates are adjusted to produce the
same outputs.
Once these changes are made, the resulting data may be sent to a 48-
466 and 424M printer to produce the same printed image in most
cases.
1 = Enable 48-466 Compatibility Mode
0 = Disable 48-466 Compatibility
Mode
6
Select GP I/O Hardware Mode:
This command is used to select
from the various General Purpose I/O modes the printer supports.
0 = Enable Custom General Purpose I/O Hardware
. This mode is a
custom solution developed for a specific customer and is not intended
to be used by other users.
1 = Enable General Purpose I/O Hardware
. When this command is
enabled, the printer provides the ability to report the current status of 4
additional inputs accessed through the P17 connector on the PCB,
report the status of 4 additional outputs accessed through the P21
connector on the PCB, to change the status of the outputs, and to
configure the inputs to generate immediate errors.
GP INPUTS:
The P17 connector is used for the GP inputs. These inputs are active
high (24VDC) and may be independently controlled.
The ^D150 command is used to report the current status of the inputs.
When issued, the printer will send the host the current status of the 4
Содержание 428T
Страница 2: ......
Страница 4: ......
Страница 12: ...viii 428T Operator s Manual 880037 0141...
Страница 60: ...Getting Started Chapter 3 3 44 428T Operator s Manual 880037 0141...
Страница 152: ...Downloadable Fonts Chapter 7 7 8 428T Operator s Manual 880037 0141...
Страница 180: ...Bar Codes Chapter 8 8 28 428T Operator s Manual 880037 0141...
Страница 186: ...Code Switching Chapter 9 9 6 428T Operator s Manual 880037 0141 Figure 9 5 Code Page 850...
Страница 190: ...Code Switching Chapter 9 9 10 428T Operator s Manual 880037 0141 Figure 9 9 Code Page 852...
Страница 194: ...Code Switching Chapter 9 9 14 428T Operator s Manual 880037 0141 Figure 9 13 Code Page 437...
Страница 198: ...Code Switching Chapter 9 9 18 428T Operator s Manual 880037 0141...
Страница 218: ...12 10 428T Operator s Manual 880037 0141...
Страница 220: ...12 12 428T Operator s Manual 880037 0141...
Страница 222: ...13 2 428T Operator s Manual 880037 0141...
Страница 224: ...13 4 428T Operator s Manual 880037 0141...
Страница 242: ...13 22 428T Operator s Manual 880037 0141...
Страница 246: ...13 26 428T Operator s Manual 880037 0141...
Страница 248: ...13 28 428T Operator s Manual 880037 0141...
Страница 249: ......