4.
Installation of Cables
This chapter describes the procedure to install the cables to the midspan unit.
4.1
AC Power Cable Installation
The following table lists the AC power cable specifications.
Table 4-1. AC Cable Specifications
Parameter
Value
Recommended cable type
North America—SJOW or SOOW
Worldwide—H05RN-F or H07RN-F
Voltage rating
300V (or better recommended)
Temperature range
–40
℃
to 65
℃
(or better recommended)
Cable size
16 AWG–18 AWG 3C
1.0 mm
2
– 1.5 mm
2
3C
Cable outer dimension
Dia. 3/16 in.–3/8 in.
Dia. 5.0 mm–9.5 mm
Approved for indoor and outdoor applications.
The following figure shows how to connect the AC power cable to the midspan unit:
Figure 4-1. Connecting the AC Power Cable to the Unit
PD-9501-xxGCO/AC
Installation of Cables
©
2022 Microchip Technology Inc.
and its subsidiaries
User Guide
DS50003340A-page 10