31
BATTERY SETUP SETTINGS
AC INPUT POWER
Level X
SELECT
ED
BOOST
XX.XV
Circuit Breaker
Inverter
AC Load
Circuit breaker must be placed within 1m from the Inverter.
Generator
10.5 AC Input Power From Generator
To change the
AC INPUT POWER
settings, Press
This allows the inverter to extract the maximum amount of power from a generator.
The inverter constantly monitors the Voltage from the generator and then applies maximum charge.
LEVEL 1
is the highest load to the generator while.
LEVEL 6
is the minimum.
The factory default LEVEL is 1.
This setting only needs to be adjusted if there is a generator connected.
When a generator is running the generator will supply the AC Load first and the inverter charges the
batteries with any excess power created from the generator
.
Always install a generator with a circuit breaker or contactor connection
Keep the circuit breaker off until the generator is running fully.
Turn of the circuit breaker before switching off the generator.
To change the Menu press
, the menu changes to Battery Boost Voltage
10.6 Battery Boost Voltage
To change the
BATTERY BOOST
settings, Press
This allows the user to adjust the
BATTERY BOOST
voltage.
The boost settings can be changed as follows:
10.6.1 Battery Boost Voltage Settings
Table 10-2A: Battery Setup - Battery Boost Voltage Firmware V21R1
48V System
51.6
52.0
Default
– Lithium
54.4
54.8
55.2
55.6
56.8
Default
– Lead Acid
57.6
58.8
62.0
“Please consult your battery supplier for the correct battery charging specifications.
To change the Menu press
, the menu changes to Battery Float Voltage