25
WIDTH
CAL
FLOW
CAL
MIN
FLOW
ADJUST
RATE
TARGET
RATE
SPEED
CAL
INLINE
BYPASS
TEST
SPEED
VOLUME /
MINUTE
DISTANCE
AREA /
HOUR
VOLUME
(1) (2) (3)
RATE
SPEED
AREA
(1) (2) (3)
ON
OFF
1
2
3
4
5
B O O M S
RUN
HOLD
CAL
AUTO
MAN
RESET
ON / OFF
____
APPLICATION RATE
TANK
___
AUTO
The AREA, DISTANCE and VOLUME counters maintain a
running count during operation regardless of the position
of the rotary switch. When any of these counters reach their
maximum capacity, or when you want to start a new count,
the value may be reset to zero by performing the following
routine. Counter pairs may be reset independently of other
counter pairs.
1. Turn the booms OFF or put the system in HOLD.
2. Turn the rotary switch to the counter to be reset.
3. To reset distance turn the rotary switch to DISTANCE
and simply press and hold the RESET button until the
display reads zero. The display will show the word
CLEAr
during this process, and will show 0.0 when
reset to zero is complete.
4. To reset the volume and area counters; there are three
independent AREA counters, paired with three VOLUME
counters. The active pair of counters is indicated by the
small numbers in the lower right area of the display (1,2,
or 3) when the rotary switch is in the AREA or VOLUME
position. Select the pair of counters you want to use
by pressing the “+” button. The small number will
increment each time the “+” button is pressed (from 1
to 3, then rolls back to 1). DO NOT attempt to select the
counter number by using the “-” button, because that
will clear the active pair of counters if held for 1 second.
If the “-” button is accidentally pressed, the console will
display “CLEAr” to alert the user that the counters will
be cleared. If the user continues to hold the “-” button
for 1 second “CLEAr” will disappear and be replaced by
.0, indicating that the selected pair of counters has been
cleared.
Clearing Counters
When the desired counter number is displayed, press the
“-” (RESET) button and “CLEAr” will be displayed.
NOTE:
holding the “-” (RESET) button for 1 second will clear both
the #3 AREA counter and the #3 VOLUME counter whether
the rotary switch is in the AREA or the VOLUME position.
If
the “-” button is released before 1 second has elapsed, the
counters will not be cleared and the “CLEAr” message will
be replaced with the previous total.
WIDTH
CAL
FLOW
CAL
MIN
FLOW
ADJUST
RATE
TARGET
RATE
SPEED
CAL
INLINE
BYPASS
TEST
SPEED
VOLUME /
MINUTE
DISTANCE
AREA /
HOUR
VOLUME
(1) (2) (3)
RATE
SPEED
AREA
(1) (2) (3)
ON
OFF
1
2
3
4
5
B O O M S
RUN
HOLD
CAL
AUTO
MAN
RESET
ON / OFF
____
APPLICATION RATE
TANK
___
HOLD
V
2
WIDTH
CAL
FLOW
CAL
MIN
FLOW
ADJUST
RATE
TARGET
RATE
SPEED
CAL
INLINE
BYPASS
TEST
SPEED
VOLUME /
MINUTE
DISTANCE
AREA /
HOUR
VOLUME
(1) (2) (3)
RATE
SPEED
AREA
(1) (2) (3)
ON
OFF
1
2
3
4
5
B O O M S
RUN
HOLD
CAL
AUTO
MAN
RESET
ON / OFF
____
APPLICATION RATE
TANK
___
HOLD
V
3
WIDTH
CAL
FLOW
CAL
MIN
FLOW
ADJUST
RATE
TARGET
RATE
SPEED
CAL
INLINE
BYPASS
TEST
SPEED
VOLUME /
MINUTE
DISTANCE
AREA /
HOUR
VOLUME
(1) (2) (3)
RATE
SPEED
AREA
(1) (2) (3)
ON
OFF
1
2
3
4
5
B O O M S
RUN
HOLD
CAL
AUTO
MAN
RESET
ON / OFF
____
APPLICATION RATE
TANK
___
HOLD
V
1
Display indicates counter pair #2 is selected
Display indicates counter pair #3 is selected
Display indicates counter pair #1 is selected
MAN
HOLD
3
WIDTH
CAL
FLOW
CAL
MIN
FLOW
ADJUST
RATE
TARGET
RATE
SPEED
CAL
INLINE
BYPASS
TEST
SPEED
VOLUME /
MINUTE
DISTANCE
AREA /
HOUR
VOLUME
(1) (2) (3)
RATE
SPEED
AREA
(1) (2) (3)
ON
OFF
1
2
3
4
5
B O O M S
RUN
HOLD
CAL
AUTO
MAN
RESET
ON / OFF
____
APPLICATION RATE
TANK
___
HOLD
V
3
After the “-” (RESET) button has been held for 1 second, the
“CLEAr” message will be replaced by “.0”, indicating that
counter pair #3 has been cleared.
Operation
(cont)
Resetting System Counters
Содержание MT-3405F II
Страница 1: ...MT 3405F II Dual Display Automatic Rate Controller Reference Manual...
Страница 7: ...7 System Layout S e c t i o n 1 5 c o n n e c t o r s SERVO VALVE...
Страница 8: ...8 Wiring Diagram...
Страница 34: ...34 Appendices...
Страница 61: ...61 NOTES...