17
Illustration 12
Calibration
English or Metric?
NOTE: In metric, the width will have a decimal point,
in English there is no decimal point. Also, changing
from En glish to Met ric mode may change or alter any
previously en tered cal i bra tion values. After switch ing
mea sure ment modes, con firm that all cal i bra tion val ues
are correct.
WIDTH
CAL
FLOW
CAL
MIN
FLOW
ADJUST
RATE
TARGET
RATE
SPEED
CAL
INLINE
BYPASS
TEST
SPEED
VOLUME /
MINUTE
DISTANCE
AREA /
HOUR
VOLUME
(1) (2) (3)
RATE
SPEED
AREA
(1) (2) (3)
ON
OFF
1
2
3
4
5
B O O M S
RUN
HOLD
CAL
AUTO
MAN
RESET
V 1 2 3 4 5
ON / OFF
____
APPLICATION RATE
TANK
___
CAL HOLD
Press to
enter or exit
calibration
mode.
Press to increase or
decrease values.
Red warning light will
be lit when in CAL.
Illustration 11
WIDTH
CAL
FLOW
CAL
MIN
FLOW
ADJUST
RATE
TARGET
RATE
SPEED
CAL
INLINE
BYPASS
TEST
SPEED
VOLUME /
MINUTE
DISTANCE
AREA /
HOUR
VOLUME
(1) (2) (3)
RATE
SPEED
AREA
(1) (2) (3)
ON
OFF
1
2
3
4
5
B O O M S
RUN
HOLD
CAL
AUTO
MAN
RESET
MANAUTO
CALHOLD
V 1 2 3 4 5
ON / OFF
____
APPLICATION RATE
TANK
___
The MT-3405F
TM
II is capable of displaying in for ma tion in
En glish or standard Metric measurement. The MT-3405F
TM
II
is shipped from the factory programmed for English.
NOTE:
The following procedures will also load factory default
calibration values. To simply change units without
loading defaults, see the “Special Calibration” section.
METRIC
• You must be in HOLD or have all booms OFF to enter
Cal. To activate the Metric mode, turn power OFF
and place the ro ta ry switch at
“AREA.”
Hold down
both the
“CAL” and “-”
keys and turn power ON.
See
Il lus tra tion 11.
The con sole will display LOAd. Once
LOAd is displayed, release the two keys. To “lock-in”
Metric mode you must enter and exit cal i bra tion. Press
and hold the CAL key until “CAL” icon appears on the
display. The con sole is now in cal i bra tion and Metric
mode is selected. Exit CAL by pressing and holding
the “CAL” key until CAL disappears from the display
(ap prox i mate ly 1 second).
NOTE: You must exit CAL to lock in Metric units.
ENGLISH
• You must be in HOLD or have all booms OFF to enter
Cal. To activate the English mode, turn power OFF and
place the ro ta ry switch in the
VOLUME
position. Hold
down both the
“CAL” and “-”
keys and turn power ON.
The con sole will display LOAd. Once LOAd is displayed,
release the two keys. To “lock-in” English mode you
must enter and exit cal i bra tion. Press and hold the CAL
key until “CAL” lights on the display. The console is
now in cal i bra tion and English mode is selected. Exit
CAL by pressing and holding the “CAL” key until CAL
disappears from the display (approximately 1 second).
NOTE: You must exit CAL to lock in English units.
Entering Calibration Values
To enter or change any of the system’s calibration values,
you must enter calibration mode. To enter calibration
mode, STOP the vehicle, turn all booms OFF or put the
console in HOLD and press and hold the CAL button until
the “CAL” icon appears (approximately one second).
(NOTE:
Calibration may be entered while moving, but it is not
rec om mend ed to attempt calibration while the vehicle is
mov ing.)
The console will remain in calibration mode, with
the RED warning light illuminated until you exit calibration
or turn power OFF.
Once in calibration mode, you may change any one, all, or
none of the values, in any order.
*
To select a calibration
position, simply turn the rotary selector to the desired
po si tion. Calibration positions are identified by the WHITE
labeling on each side of the rotary selector. All values are
entered and adjusted using the
“+” and “-”
but tons on the
front panel.
Note: TEST SPEED is NOT a calibration setting. It simulates
vehicle speed during Pre-Application System Checkout.
This procedure is described on page 33.
Hold the “CAL” key again for 1 second to exit calibration.
“CAL” will disappear from the display.
NOTE: You must exit CAL to save changes.