
The AREA, DISTANCE and VOLUME counters maintain a
running count during operation regardless of the position
of the rotary switch. When any of these counters reach
their maximum capacity, or when you want to start a new
count, the value may be reset to zero by performing the
following routine. Counters may be reset independently of
each other.
1. Put the system in
HOLD.
2. Turn the rotary switch to the counter to be reset.
3. To reset distance turn the rotary switch to DISTANCE and
simply press and hold the RESET button until the display
reads zero. The display will show the word “CLEAr” during
this process, and will show 0.0 when reset to zero is
complete.
4. To reset the volume and area counters; there are three
independent AREA counters, paired with three VOLUME
counters. The active pair of counters is indicated by the
small numbers in the lower right area of the display (1,2,
or 3) when the rotary switch is in the AREA or VOLUME
position. Select the pair of counters you want to use by
pressing the “+” button. The small number will increment
each time the “+” button is pressed (from 1 to 3, then rolls
back to 1).
DO NOT
attempt to select the counter number
by using the “-” button, because that will clear the active
pair of counters if held for 2 seconds. If the “-” button is
accidentally pressed, the console will display “CLEAr” to
alert the user that the counters will be cleared. If the user
continues to hold the “-” button for 2 seconds “CLEAr”
will disappear and be replaced by 0.0, indicating that the
selected pair of counters has been cleared.
T
o
S
elect
a
P
air
of
AREA
and
VOLUME C
ounters
:
Verify that the desired counter pair is selected, or use the “+”
button to select.
WIDTH
CAL
FLOW
CAL
MIN
FLOW
TARGET
RATE
SPEED
CAL
TEST
SPEED
VOLUME /
MINUTE
DISTANCE
AREA /
HOUR
VOLUME
(1) (2) (3)
RATE
SPEED
AREA
(1) (2) (3)
TANK
CAL
RESET
MAN
HOLD
CALHOLD
1
II
TANK
VOL
TANK
ALARM
RUN
HOLD
Display indicates counter pair #2 is selected
WIDTH
CAL
FLOW
CAL
MIN
FLOW
TARGET
RATE
SPEED
CAL
TEST
SPEED
VOLUME /
MINUTE
DISTANCE
AREA /
HOUR
VOLUME
(1) (2) (3)
RATE
SPEED
AREA
(1) (2) (3)
TANK
CAL
RESET
MAN
HOLD
CALHOLD
3
TANK
VOL
TANK
ALARM
RUN
HOLD
II
WIDTH
CAL
FLOW
CAL
MIN
FLOW
TARGET
RATE
SPEED
CAL
TEST
SPEED
VOLUME /
MINUTE
DISTANCE
AREA /
HOUR
VOLUME
(1) (2) (3)
RATE
SPEED
AREA
(1) (2) (3)
TANK
CAL
RESET
CALHOLD
1 2 3 4 5
II
TANK
VOL
TANK
ALARM
RUN
HOLD
WIDTH
CAL
FLOW
CAL
MIN
FLOW
TARGET
RATE
SPEED
CAL
TEST
SPEED
VOLUME /
MINUTE
DISTANCE
AREA /
HOUR
VOLUME
(1) (2) (3)
RATE
SPEED
AREA
(1) (2) (3)
TANK
CAL
RESET
MAN
HOLD
CALHOLD
2
II
TANK
VOL
TANK
ALARM
RUN
HOLD
Resetting System Counters
Not Applicable to the
B
atch
(t
ank
F
ill
)
M
ode
28
Display indicates counter pair #3 is selected
Display indicates counter pair #1 is selected
Содержание FLOWTRAK II
Страница 1: ...Application Monitor Reference M a n u a l...
Страница 36: ...Appendices 36...
Страница 43: ......