19
WIDTH CAL:
Enter the effec tive working width of the
entire boom, in inch-
es (meters). Your
“working” width per
boom section will be
the number of nozzles on the boom section
times the nozzle spacing in inches (mm). For
example, if you have 7 nozzles spaced at 20
inches, the working width of the boom section
is 140 inches.
WIDTH
CAL
AREA
(1) (2) (3)
TARGET RATE:
Enter the value for the desired target
application rate in gallons per acre (liters per
hectare) or lbs. of N per acre (kgs of N per
hectare). During operation, the warning light
will flash if the actual application rate is +/-
10% from the calibrated target rate.
TARGET
RATE
RATE
TANK ALARM SET POINT:
Enter the tank alarm set
point in gallons (liters) or lbs. (kgs) NH3. Use the “+” and
“-” buttons to set the level where the Warning LED starts
flashing and the word “FILL” flashes on the
display. Range is OFF or 1-65,535. When the
tank value drops below
the set point, the alarms
will notify the user that
the tank level is low.
Note: this feature is inoperative if the system is set up in the
(Tank) FILL mode.
See Special Calibration (pages 25-26) and
Tank fill Operation (page 30) for setup and operation details
for the Tank FILL mode.
TANK
ALARM
AREA /
HOUR
TANK VOL:
If using the Tank feature, this setting can be
used to enter the volume of the tank in gallons (liters, lbs.
NH3). Use the “+” and “-” buttons to choose OFF or any value
from 1-65,535. Then when the tank is filled,
the tank counter can be reset to full by simply
turning the rotary switch to the TANK position
and pressing the “+”
button. Depending on
the “UNITS” setting, the
TANK SIZE units will be
either gallons or liters. If “material” is set to NH3, the Tank
Size will be in lbs. or kg. Anhydrous Ammonia (NH3).
Note:
the TANK VOLUME remaining feature does not work if the
system is programmed in the (Tank) FILL mode.
See page
30 for setup and operation details for the Tank FILL mode.
TANK
VOL
TANK
SPEED CAL:
This position is used to calibrate the speed
sensor for ac cu rate
speed and dis tance
measurement. When
this position is selected,
the display will show THE SPEED CAL value.
SPEED
CAL
DISTANCE
Calibration
(cont)
Entering Calibration Values