iID
®
PENsolid UHF
User Manual
UserMan-iID PENsolid UHF-002E.DOCX
© 2017 microsensys
QuickStartGuide
Manner of functioning
iID
®
PENsolid may be used as RFID read/write device with USB- or Bluetooth
™
interface or RFID scanner
using the integrated scan button. See following table for available configurations, for further information see
iID
®
SPC/MPC related documents.
Functionality
Operation mode
configuration
Interface
Remark
Read/write interface
DOC
USB
Bi-directional USB communication,
based on iID
®
driver engine, device
configuration
Bluetooth™ HID (human
interface device / key-
board mode)
SPC
Bluetooth™ HID Uni-directional communication, script
with output functionality on device
iID
®
PENsolid is delivered in SPC/HID mode. Please adjust operation mode connecting to a PC via USB
interface. Using iID
®
interface configuration tool you may configure the device according your requirements
before first usage. Microsensys provides sample scripts for device usage in SPC mode, which are available
for download in iID
®
interface configuration tool.
iID
®
PENsolid buttons support following functionalities:
Button
Functionality
(1) ON/OFF
Power on device, power off device when pressed for
3 seconds
(2) SCAN button
Perform scan (while device in SPC mode)
(1) and (2)
Keep holding (1) and (2) while device is off until lights
come up will switch on device and perform
Bluetooth™ reset.