background image

iID

®

PENsolid UHF 

User Manual 

UserMan-iID PENsolid UHF-002E.DOCX  

© 2017 microsensys 

QuickStartGuide 

FCC compliance statement 

 

IC compliance statement 

 

 

These devices comply with part 15 of the FCC Rules. Operation is subject to the following two conditions: 

 

1. These devices may not cause harmful interferences; 

2. These devices must accept any interference received, including interference that may cause undesired 
operation. 

 

The following figures list the Grant by FCC ID Number for each of the following devices: 

 

FCC ID:  

ZLCPENSOLIDUFX 

 
Please refer to the FCC’s website ( 

http://www.fcc.gov/

 ) to view the grant and related documentation. 

 

CAUTION ! 

Exposure  to  Radio  Frequency  Radiation.  The  radiated  output  of  this  device  is  far  below  the  FCC  radio 
frequency exposure limits. Nevertheless, the device shall be used in such a  manner that the potential for 
human contact during normal operation is minimized. In order to avoid the possibility of exceeding the FCC 
radio frequency exposure limits, human proximity to the antenna shall not be less than 20cm (8inches) during 
normal operation. These devices may not be co-located with any other transmitter or transmitter antenna. 

 

NOTE: 

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to 
part  15  of  the  FCC  Rules.  These  limits  are  designed  to  provide  reasonable  protection  against  harmful 
interferences  when  the  equipment  is  operated  in  a  commercial  environment.  This  equipment  generates, 
uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction 
manual,  may  cause  harmful  interference  to  radio  communications.  Operation  of  this  equipment  in  a 
residential area is likely to cause harmful interference in which case the user will be required to correct the 
interference at his own expense. 

Cha

nges or modifications not expressly approved by Microsensys GmbH could void the user’s authority to 

operate  the  equipment  described  in  the  manual. 

This  device  contains  Bluetooth™  module  FCC  ID: 

QOQWT12. 

 

Industry Canada ID:  21228-PENSOLIDUFX, contains Bluetooth

™ module IC ID: 5123A-BGTWT12A 

 

This device complies with Industry Canada RSS-210. Operation is subject to the following two conditions:  

(1) this device may not cause interference, and  

(2) this device must accept any interference, including interference that may cause undesired operation of 
the device. 

  
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio RSS-210. 
L’exploitation est autorisée aux deux conditions suivantes :  

(1) 

l’appareil ne doit pas produire de brouillage, et  

(2)  l’utilisateur  de  l’appareil  doit  accepter  tout  brouillage  radioélectrique  subi,  même  si  le  brouillage  est 
susceptible d’en compromettre le fonctionnement. 

Содержание iID PENsolid UHF

Страница 1: ... Versions iID PENsolid UHFcc System iID 4000 EU RFID Pen Style Read Write Unit v1 00 with RTC MEM BT USB Li accu Display LEDs for power BT status Buttons SCAN F1 F2 System iID4000 EU ISO 18000 6c EPC G2 all customized Antenna P3U Operation Mode DOC SPC Bluetooth SPP HID Dimensions 120x26x20 mm Li Ion Battery 450mAh Including micro USB cable hand strap Product Code 43 72 850 xx iID PENsolid UHFcc S...

Страница 2: ... part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interferences when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in...

Страница 3: ... USB interface Battery cycles may vary from some hours to several days depending on the device configuration When the device is connected via it s USB interface the device is powered by USB power The device is available in several types supporting HF as well as UHF systems suitable for closed coupling communication with very small sized up to large RFID transponders Additionally all devices suppor...

Страница 4: ...ard mode SPC Bluetooth HID Uni directional communication script with output functionality on device iID PENsolid is delivered in SPC HID mode Please adjust operation mode connecting to a PC via USB interface Using iID interface configuration tool you may configure the device according your requirements before first usage Microsensys provides sample scripts for device usage in SPC mode which are av...

Страница 5: ... installation of further software may be required Operation mode Platform Software DOC Windows 32 64 without RT iID software package including iID driver engine optional iID tray application http www microsensys de downloads CDContent Install iID c2 ae 20tray 20application zip Windows Mobile Windows embedded handheld iID driver engine iID DEMOsoft http www microsensys de downloads CDContent Instal...

Страница 6: ...by for the manufacturer Unauthorized changes and the use of spare parts and additional devices which have not been sold or recommended by the manufacturer may cause fire electric shocks or injuries Such unauthorized measures shall exclude any liability by the manufacturer The liability prescriptions of the manufacturer in the issue valid at the time of purchase are valid for the device The manufac...

Страница 7: ...leep mode typ 5μA Idle mode typ 60mA Active mode max 400mA RFID Interface Carrier frequency EU 868 US 915MHz Implemented standards ISO18000 6c RF output power 24dBm Antenna P3U Operating distance 0 30cm depending on transponder type and environmental conditions Additional interfaces Bluetooth interface Bluetooth 2 0 USB interface USB 2 0 Operation modes DOC Direct online communication serial commu...

Страница 8: ...solid HF xxx pdf PENsolid UHF xxx pdf Product or System Documentation DOC iID SPC 01D pdf Quick iID MPC 01D pdf Contact Copyright Micro Sensys GmbH In der Hochstedter Ecke 2 99098 Erfurt Germany phone 49 0 3 61 5 98 74 0 fax 49 0 3 61 5 98 74 17 e mail info microsensys de web www microsensys de Any reproduction of this short manual in whole or in part the storage in electronic media and the transl...