13
interization
1. Disconnect supply hose from machine to allow any waler In and
above inlet fittings to drain out.
2. Drain plug on the bottom of the turbine must be drained to prevent
freeze damage to turbine housing and impeller. Drain plug is lo-
cated on the bottom side of the turbine.
3. It is important ti unrack the guncart on the MR40 & MR43, open
the shutoff valve, and allow water above lhe valve to drain out of the
sprinkler. Shutoff valve on MR50 throughMR58RL located under
the red cover should be latched in the open position as well. This
will allow any remaining water to expand out and not cause any
damage to the valve.
4. Drain guncart body by taking out draln plug localed on the bottom
elbow of the cart on all large chassis Micro Rains - MR40 through
MR5BRL.
5. Drain boost pump case by opening 1/4” ball valve as shown in left
photo. On boost pump models, disconnect the short black con-
nection hose on the side of the Micro Rain that connects the
boost pump piping to the inlet side of the machine. This allows
water in the cross-pipe to drain; preventing damage to the pipe or
flow switch.
aintenance Schedule
Fittings & Seals:
Grease fittings and seals every 100 hours.
Wheel Hubs:
Grease all wheel hubs every 100 hours.
Drum Gear:
Grease the drum gear at least twice per season.
Gearbox:
Change gearbox oil once a season with 80W/90 gear oil.
Level Wind:
Check tire pressure every 4-6 weeks.
NOTE:
Water left in poly hose may be blown out with an air compressor by coverting an Inlet fitting with an air chuck
adaptor. These fittings are available through KID Group if needed.