Laser Safety

The scanCONTROL 25xx sensors operate with a semiconductor laser having a wave-

length of 658 nm (visible/red). The laser operation is indicated visually by the LED on 

the sensor.
When operating the scanCONTROL 25xx sensors, the relevant regulations according 

to IEC 60825, Part 1 of 05/2014 and the applicable accident prevention regulations 

must be followed.
Attach the following warning labels to the cover (front side) of the sensor housing. The 

laser warning labels for Germany have already been applied. Those for other non Ger-

man-speaking countries an IEC standard label is included in delivery and the versions 

applicable to the user’s country must be applied before the equipment is used for the 

first time.

 

If the information labels are hidden in the installed state, the user must ensure 
that additional labels are fitted at the point of installation.

scanCONTROL 25xx sensors with a maximum laser power up to 8 mW are classified in 

Laser Class 2M (IIM). Attach the following warning labels to the cover (front side) of the 

sensor housing.

 

LASER RADIATION

DO NOT STARE INTO BEAM

 OR EXPOSE USERS OF

CLASS 2M LASER PRODUCT

 TELESCOPE OPTICS

IEC 60825-1: 2014

P

≤ 8 mW; P

≤ 8 mW; H ≤ 52 W/m²; 

 

= 658nm; F = 0...4 kHz; t = 1 µs...∞

COMPLIES WITH 21 CFR 1040.10 AND 1040.11 

EXCEPT FOR CONFORMANCE WITH 

IEC 60825-1 ED. 3., AS DESCRIBED IN

LASER NOTICE NO. 56, DATED MAY 8, 2019

Only for USA

Hazard to the eye via laser radiation! Consciously close your 

eyes or turn away if the laser radiation impinges on the eye.

i

 

Laser areas must be marked duarably and clearly, if the laser beam runs 
through a work or traffic area.

Содержание scanCONTROL 2500

Страница 1: ...r You will find this manual online at www micro epsilon com 2 Notes on CE Identification The following applies to the scanCONTROL 25xx EU Directive 2014 30 EU EU Directive 2011 65 EU RoHS category 9 T...

Страница 2: ...s used for the first time i If the information labels are hidden in the installed state the user must ensure that additional labels are fitted at the point of installation scanCONTROL 25xx sensors wit...

Страница 3: ...22 11 gray pink In1 6 yellow Switching input In1 GND In1 4 green Ground connection In1 In2 5 pink Switching input In2 GND In2 8 grey Ground connection In2 In3 10 purple Switching input In3 GND In3 7 b...

Страница 4: ...nal levels are switchable for all switching inputs between LLL TTL logic and HLL HTL logic LLL level Low 0 V 0 8 V high 2 4 V 5 V internal pull up resistor 10 k to 5V HLL level Low 0 V 3 V high 11 V 2...

Страница 5: ...et 169 254 x x No collision detection is implemented This is also the default setting The sensor supports DHCP This setting is activated by default and has priority over the retrieval in the link loca...

Страница 6: ...n Tools The following minimum system specification is necessary Windows 7 32 bit and 64 bit Windows 10 32 bit and 64 bit 800 MHz or faster 32 bit and 64 bit processor 512 MB RAM Screen resolution 1024...

Страница 7: ...Loosen the screws before you remove the connector from the socket Connect the shield of the power supply cable to the PE protective earth conduc tor of the main power supply Close unused connection p...

Страница 8: ...L can be accessed via GigEVision and GenICam for digital cameras via Ethernet interface SDK for fast application integration C C C and others For details how to access profile data refer to the enclos...

Страница 9: ...ms Furthermore all scanCONTROL sensor settings can be set via scanCON TROL Gateway e g Laser on off or switch User Mode Sensor parame terization Power supply Triggering Encoder Synchronization Mode co...

Страница 10: ...V 230 V 24 V 13 scanCONTROL 2510 with scanCONTROL Output Unit for Con 13 14 C D B A 750 626 Power jumper contacts Supply via power jumper contacts 24V Status voltage supply Power jumper contacts Syste...

Страница 11: ...field supply in of the OU Filter module to the power supply 0 V and 24 V resp 0 V and 5 V i The system supply and field supply should be separated to ensure the bus operation and electrical isolation...

Страница 12: ...rther Information Please refer to the enclosed online manual the section Status and Error Messages and Notes in the scanCONTROL Configuration Tools manual You will find details to the separate program...

Отзывы: