9. 

First Profile

  Now start the scanCONTROL Configuration Tools software. Click on 

Display 

Profiles

 in the main window.

If the software shows the error message 

No scanCONTROL found

 in the status 

line, please check the Ethernet connection between scanCONTROL and PC.

On the left side you can adjust the settings for your measurement task, the right side 

shows the profile data and information about the measurement.

10. 

How to Access Profile Data

Profile data of scanCONTROL can be accessed via:

 - GigEVision and GenICam for digital cameras via Ethernet interface

 - SDK for fast application integration (C, C++, C# and others)

For details how to access profile data refer to the enclosed online manual.

11. 

Transmitting Measurement Results

scanCONTROL 2510 offers the following options for transmitting measurement 

results:

 - Ethernet interface

 

ƒ

Modbus TCP protocol

 

ƒ

UDP protocol

 

ƒ

Analog output of measurement values (via optional Output Unit)

 

ƒ

Digital output of switching signals (via optional Output Unit)

 

ƒ

Fieldbus connection Profinet, Ethernet/IP, EtherCat (via optional Gateway)

 - RS422 interface

 

ƒ

Modbus RTU protocol

 

ƒ

Measurement value transmission in ASCII format

Содержание scanCONTROL 2500

Страница 1: ...r You will find this manual online at www micro epsilon com 2 Notes on CE Identification The following applies to the scanCONTROL 25xx EU Directive 2014 30 EU EU Directive 2011 65 EU RoHS category 9 T...

Страница 2: ...s used for the first time i If the information labels are hidden in the installed state the user must ensure that additional labels are fitted at the point of installation scanCONTROL 25xx sensors wit...

Страница 3: ...22 11 gray pink In1 6 yellow Switching input In1 GND In1 4 green Ground connection In1 In2 5 pink Switching input In2 GND In2 8 grey Ground connection In2 In3 10 purple Switching input In3 GND In3 7 b...

Страница 4: ...nal levels are switchable for all switching inputs between LLL TTL logic and HLL HTL logic LLL level Low 0 V 0 8 V high 2 4 V 5 V internal pull up resistor 10 k to 5V HLL level Low 0 V 3 V high 11 V 2...

Страница 5: ...et 169 254 x x No collision detection is implemented This is also the default setting The sensor supports DHCP This setting is activated by default and has priority over the retrieval in the link loca...

Страница 6: ...n Tools The following minimum system specification is necessary Windows 7 32 bit and 64 bit Windows 10 32 bit and 64 bit 800 MHz or faster 32 bit and 64 bit processor 512 MB RAM Screen resolution 1024...

Страница 7: ...Loosen the screws before you remove the connector from the socket Connect the shield of the power supply cable to the PE protective earth conduc tor of the main power supply Close unused connection p...

Страница 8: ...L can be accessed via GigEVision and GenICam for digital cameras via Ethernet interface SDK for fast application integration C C C and others For details how to access profile data refer to the enclos...

Страница 9: ...ms Furthermore all scanCONTROL sensor settings can be set via scanCON TROL Gateway e g Laser on off or switch User Mode Sensor parame terization Power supply Triggering Encoder Synchronization Mode co...

Страница 10: ...V 230 V 24 V 13 scanCONTROL 2510 with scanCONTROL Output Unit for Con 13 14 C D B A 750 626 Power jumper contacts Supply via power jumper contacts 24V Status voltage supply Power jumper contacts Syste...

Страница 11: ...field supply in of the OU Filter module to the power supply 0 V and 24 V resp 0 V and 5 V i The system supply and field supply should be separated to ensure the bus operation and electrical isolation...

Страница 12: ...rther Information Please refer to the enclosed online manual the section Status and Error Messages and Notes in the scanCONTROL Configuration Tools manual You will find details to the separate program...

Отзывы: