Page 75
Setting Sensor Parameters
optoNCDT 1750
7.6.3.2
Output Scaling with the Select Button
LED
State
Measuring
Green, yellow,
depends on
measuring position
Color according
to measuring
position
flashes red
approx. 1 Hz
flashes green
approx. 1 Hz
Key
Select
Position the
measuring
object (Teach 1)
Position the
measuring
object (Teach 2)
Key
Select
Key
Select
red
t 0
5 min
2 s
30 s
30 s
t 1
t 2
t 3 t 4
t 6 t 7
t 8
t 5
yellow
yellow
min.
30 ms
min.
30 ms
Fig. 39 Flow chart for output scaling
LED
State
Measuring
Green, red, yellow
depends on
measuring position
Color according
to measuring
position
flashes red approx. 1 Hz
red
t 0
5 min
2 s
200 ms
Switch output 1
t 5 - t 3 = 2 s
5 ... <10 s
t 1
t 2
t 3 t 4
t 5
yellow
Hold the key
Select
Fig. 40 Flow chart for resetting the output scaling
When the Select button is pressed longer than 10 s or not within the time frame when resetting the output
scaling, the
State
LED will this display as error. The
State
LED then flashes for two seconds with 8 Hz.
i
Preparation
- Deactivate key
lock (menu Sys-
tem settings)
- Teaching process
with Select button
(menu Outputs)