A 3.2.2.5
PASSWD, Change Password
PASSWD <Old Password> <New Password> <New Password>
Changes the password for the PROFESSIONAL level.
The old password must be entered once, and the new password twice. If the new passwords do not match,
an error message is displayed. A password may only contain letters (A to Z) and numbers, but no letters with
accents or umlauts. Upper and lower case are distinguished. The maximum length is 31 characters.
A 3.2.3
Triggering
The multi-function input also serves as trigger input
A 3.2.3.1
TRIGGERLEVEL, Active level triggering
TRIGGERLEVEL HIGH | LOW
- HIGH: Edge triggering: Rising edge, level triggering: High-active
- LOW: Edge triggering: Falling edge, level triggering: Low-active
A 3.2.3.2
TRIGGERMODE
TRIGGERMODE EDGE | PULSE
Defines the trigger type.
- PULSE: Level triggering
- EDGE: Edge triggering
A 3.2.3.3
TRIGGERSOURCE, Trigger source
TRIGGERSOURCE NONE | MFI | SYNCIO | SOFTWARE
- NONE: Triggering is deactivated
- MFI: Use multi-function input for triggering.
- SYNCIO: Use synchronization ports for triggering
- SOFTWARE: Triggering is controlled by the TRIGGERSW command