Page 10
Safety
optoNCDT 1420
Mount the sensor only to the existing holes on a flat surface. Clamps of any kind are not permitted
> Damage to or destruction of the sensor
The supply voltage must not exceed the specified limits.
> Damage to or destruction of the sensor
Protect the sensor cable against damage. Attach the cable load-free, hold the cable after appr. 25 cm e.g. zip
tie.
> Destruction of the sensor
> Failure of the measuring device
Avoid constant exposure of sensor to splashes of water.
> Damage to or destruction of the sensor
Avoid exposure of sensor to aggressive media (detergents, cooling emulsions).
> Damage to or destruction of the sensor
1.3
Notes on CE Marking
The following apply to the optoNCDT 1420:
- EU directive 2014/30/EU
- EU directive 2011/65/EU, “RoHS“ category 9
Products which carry the CE mark satisfy the requirements of the EU directives cited and the European
harmonized standards (EN) listed therein. The EU Declaration of Conformity is available to the responsible
authorities according to EU Directive, article 10, at
MICRO-EPSILON MESSTECHNIK
GmbH & Co. KG
Königbacher Straße 15
94496 Ortenburg / Germany
The sensor is designed for use in industrial environments and meets the requirements.