Cable Assembling
The cable gland M12x1,5 of the controller allows the use of cables with a diameter of 3 to 5 mm.
Remove the isolation from the cable (40 mm power supply, 50 mm signal outputs, 60 mm functional inputs).
Cut the shield down to approximately 5 mm and spread the strands out. Extract about 4 mm of the wire
isolation and tin the wire ends.
Place the pressing screw, the rubber washer and the metal washers of the cable gland one after the other
onto the prepared cable end. Spread the strands and fix the shield between two of the metal washers. Insert
the cable into the cable gland until the limit stop. Screw the cap tight.
Every single wire may be connected to the according screw clamps according to their colors.
Use shielded cables only. The