Page 21
optoNCDT ILR2250
Installation and Assembly | Electrical Connections ILR2250-100-IO
5.5.3
Supply Voltage
Nominal value 24 VDC (10 ... 30 V,
P
< 4 W)
The ILR2250-100-IO sensor is supplied via the IO-Link master.
Only turn on the power supply after wiring has been completed.
Alternatively, you connect the
G
(brown)
and
L (blue)
inputs on the sensor to a 24 V power supply.
ILR2250
G
L
10 ...
30 VDC
Sensor PC1100-0,3 IO-Link adapter PC1000-x IO-Link
Explanation
Pin
Pin, 12 poles
Pin, 5 poles
Pin
Wire color
G
G
1
1
Brown
U
B
L
L
3
3
Blue
Supply ground
Fig. 19 Supply voltage connection
Voltage supply only for measuring devices, not to be used for drives or similar sources of impulse interference at the
same time.
MICRO-EPSILON recommends using the optionally available PS2020 power supply,
, for the sensor.