background image

EDM-MD Series 
Installation Manual

 

 

 

 

 

Page 6

 

 

 

 

Accessories 

-

 

Sensor / Threshold Safety - Microwave or Infrared detection sensors and safety beam products available. 

-

 

Function Selector Switch – 4 Position Rotary switch available (Closed, Exit, Auto, Open & Emergency Exit 
Option) 

-

 

Door Profile Solutions – Various Fixed and Moving profile designs available without glass. 

-

 

Frameless Glass Brackets – Fitting Brackets for 10mm and 12mm Glass thickness available without glass. 

-

 

Floor Guides – Various floor guides for framed and frameless glass doors available. 

 

For more information visit: 

www.micomautodoor.com

 or E-mail: 

[email protected]

  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание EDM-MD Series

Страница 1: ...stallation Manual Page 1 MICOM AUTODOOR Automatic Sliding Door Operator Model EDM MD Original Instructions EN16005 Compliant INSTALLATION MANUAL OSAKA JAPAN www micomautodoor com REVISED DATE JUNE 201...

Страница 2: ...r supply whilst door s in motion Ensure sliding door travel area is clear before switching power switch ON Keep fingers clothing hair clear of belt and all moving parts Protective gloves should be wor...

Страница 3: ...ing Doors 3 5 Smooth Operation 3 6 Power On 4 Teaching Learning Operation 4 1 Teaching Learning 5 Set Up Operation 5 1 Motor Gear Box 5 2 Control Box 6 Setting Table 6 1 Basic Setting Code 6 2 Hold Op...

Страница 4: ...accessible LED visual display found on EDM MD Control box face Connections for sensor and other inputs are located as either an independent input terminal on the rail or by adding MICOM Sensor and Ba...

Страница 5: ...ange of sensors such as BEA IXIO S Optex 0A Axis T 1 3 Delivery MICOM EDM MD Series can be supplied in several formats as follows Complete Operator consisting of Base Rail Cover Control Box Connection...

Страница 6: ...vailable Closed Exit Auto Open Emergency Exit Option Door Profile Solutions Various Fixed and Moving profile designs available without glass Frameless Glass Brackets Fitting Brackets for 10mm and 12mm...

Страница 7: ...y 2 Hanger Roller Bracket with Belt Bracket Link Assembly Double Leaf 3 Tooth Belt 4 Hanger Roller Bracket with Belt Bracket Link Assembly Single Leaf 5 EDM MD Control Box 6 Base Rail with Side Cover...

Страница 8: ...n Option outside of EU 2 2 1 SMB No Description 1 SMB output to Control Box 2 Internal Sensor Input 3 External Sensor Input 4 LED Error Indicator 5 DIP Switch 6 E Lock Timer 7 Side Screen Sensor Input...

Страница 9: ...witch 4 Position Key Note If SMB is not used please refer to section 10 1 for MICOM Function Selector 4 Position Symbol Description Closed Locked Exit Only Automatic Hold Open Exit In case Locked is s...

Страница 10: ...n access at all times during works being carried out Positioning and Installing base rail Refer to below EDM MD Drawing to find correct measurement of base rail position Ensure hanger roller brackets...

Страница 11: ...EDM MD Series Installation Manual Page 11 3 3 EDM MD Front View...

Страница 12: ...orrectly installed Refer to wiring diagrams Sec 8 The power switch is located to the right of motor fixed to the underside of the base rail 4 Teaching Learning Operation CAUTION Ensure that the door t...

Страница 13: ...learn it s stoke In case of a malfunction or in the event that the stored data is affected by electric noise during its operation the controller can be recovered by another RESET We recommend taking...

Страница 14: ...T Set to RUN then teaching starts How to change setting UP SET ON OFF Change LED 1 value OFF ON LED 2 flash ON OFF Change LED 2 value OFF ON Value is fixed LED 1 2 lights are on Repeat this to change...

Страница 15: ...ogramming mode Slide switch from RUN to PROG See setting table Sec 6 5 SW4 Note After changing setting of SW4 turn the main power OFF ON to save adjustment SW1 Opening direction SW2 RS function Ratche...

Страница 16: ...A 5 Setting of close high speed 6 Close Low Speed 0 A 4 Setting of close low speed 7 Close Brake Force 0 A 5 Setting of close brake force 8 Close Force 0 A 3 Setting of close motor torque 9 Partial Op...

Страница 17: ...in the threshold and not detected by safety devices the following obstruction detection function will ensure safe operation as follows 7 1 During closing travel On contact with object doors will reve...

Страница 18: ...200 240V AC 0 7A Power Output 24V DC 300mA Manual door opening closing force during power failure 24 5 39 2N 2 5 4kgf 29 4 49 0N 3 5kgf Open Door Speed Adjustable 160 500mm s Close Door Speed Adjustab...

Страница 19: ...ction Selectors are easy to install and operate Supplied in a fire retardant black plastic mount box with attractive cover design in white our function selectors can be fitted to walls or aluminium fr...

Страница 20: ...EDM MD Series Installation Manual Page 20 10 2 Wiring Drawing MICOM Function Selector Switch 4 Position with Rotary Knob Available in 2 configurations 10 2 1 Rotary Function Selector 4 Position...

Страница 21: ...EDM MD Series Installation Manual Page 21 10 2 2 Rotary Function Selector Switch 4 Positions with Push Button Exit...

Страница 22: ...en Time 1 F Steps 1 1 Open High Speed 500mm s MAX 0 A Steps 7 2 Open Low Speed 0 A Steps 4 3 Open Brake Force 0 A Steps 5 4 Open Force 0 A Steps 5 5 Close High Speed 400mm s MAX 0 A Steps 5 6 Close Lo...

Страница 23: ...on House Regent Centre Gosforth Newcastle Upon Tyne NE3 3PF U K Tel 0044 0191 2336323 Fax 0044 0191 2840222 E Mail info micomautodoor com Copyright 2011 MICOM Autodoor The contents of the document are...

Отзывы: