EDM-MD Series
Installation Manual
Page 15
E1 : Open error (Obstruction during the opening cycle)
E2 : Closer error (Obstruction during the closing cycle)
E4 : Loose belt (Longer stroke than stored data)
E6 : E-lock error (no un-lock signal input)
‘PROGRAM’ Mode
When in PROGRAM mode, changes to operational parameter values can be made.
(To entre Programming mode: Slide switch from RUN to PROG.)
See setting table. Sec 6.
5.SW4
Note : After changing setting of SW4, turn the main power OFF/ON to save
adjustment.
SW1 : Opening direction
SW2 : RS function (Ratchet or Flip Flop)
SW3 : CE (Closed End) Output
ON – Closed end output signal is given whilst door is open
OFF – Closed end output signal if given whilst door is closed
SW4 : E-lock (set OFF when E-lock is connected (YES)
6.Motor Plug
Connection of Motor to Control by Plug in
7. Sensor Harness
Connection of Sensor Harness to Control by Plug in