Easidew DryCheck User’s Manual
20
97108 Issue 13, July 2017
OPERATION
P
SET
x 5
Main display
SET
Set baud
Set Address
0=1200
,
1=2400
2=4800
,
3= 9
6
00
4=19200
SET
SET
Set Parity
Set number of
stop bits
0000 = 1 stop bit
0001 = 2 stop bits
0000 = None
0001 = Odd
0002 = E
v
en
SET
SET
Main Display
(°F)
P
Range between
0001 and 0247
Figure 14
Set-up Data Communications Parameters