Operator's Manual
Maintenance
preVentiVe OperatOr Maintenance cHart
PROCEDURE
DAILY
3 MONTHS
6 MONTHS
9 MONTHS
2 MONTHS
Check water pump oil level
X
Oil leak visual inspection
X
Fuel leak visual inspection
X
Water leak visual inspection
X
Hose visual inspection
X
Water strainer inspection
X
High pressure nozzle inspection
X
Fuel filter/water sep. inspection
X
Change water pump oil **
X
X
X
X
Replace high pressure nozzle***
X
X
X
X
Inspect belt
X
X
X
X
Check burner air adjustment
X
X
X
X
Test water pressure*
X
X
X
X
Test water temperature*
X
X
X
X
Replace fuel filter
X
X
Test fuel pressure*
X
Delime coil****
X
Test voltage and amp draw*
X
Inspect fuel pump filter*
X
Check burner electrodes*
X
Replace fuel nozzle*
X
* Should be performed by an authorized service technician.
** The pump oil must be changed after the first 50 hours of operation and every 500 hours or 3 months, whichever
comes first.
*** High pressure nozzle should be replaced whenever pressure is less than 85%.
**** Scale build up will vary with mineral content in the water and amount of usage. Deliming can range from weekly
to yearly maintenance.
Содержание HEO Series
Страница 10: ...10 Operator s Manual HEO series features HEO SERIES FEATURES 112309 CH ...
Страница 31: ...Manuel de l utilisateur Laveur haute pression à eau chaude 31 NOTES ...
Страница 61: ...Manuel de l utilisateur Laveur haute pression à eau chaude 61 NOTA ...
Страница 62: ...62 Manuel de l utilisateur Laveur haute pression à eau chaude NOTA ...
Страница 63: ...Manual del operator de lavadoras de presión de agua caliente 63 NOTA ...
Страница 93: ...Manual del operator de lavadoras de presión de agua caliente 93 ...
Страница 94: ...94 Manual del operator de lavadoras de presión de agua caliente ...