26
Operator’s Manual
PREPARATION FOR STORAGE
When a generator is in storage, air may condense and mois-
ture may appear on the windings. In order to minimize con-
densation, always store the generator in a dry area. Cover the
generator with a protective cover that extends to the ground.
The cover should remain loose around the generator in order
to allow proper ventilation.
The generator must not be stored in ambient temperatures
greater than 131°F (55°C) as this can damage the CO Detector.
Wait until the generator has cooled before covering it. NEVER
operate the genrator with the cover installed. It could ignite
and cause damage.
STORAGE FOR 1 TO 3 MONTHS
Remove any dirt, rust, grease, and oil from the generator. DO
NOT use a pressure washer to clean the generator. Inspect the
exterior. Make any necessary repairs.
Add fuel stabilizer to the fuel tank to prevent the gasoline from
going bad. Start and run the engine for 5 minutes to ensure
that the fuel stabilizer has been pulled in to the carburetor.
Shut off the engine and allow the engine to cool.
Turn the generator switch to the off “O” position.
Move the generator to the storage place.
Cover the generator.
STORAGE FOR MORE THAN 3 MONTHS
Remove any dirt, rust, grease, and oil from the generator. DO
NOT use a pressure washer to clean the generator. Inspect the
exterior. Make any necessary repairs.
WARNING: GASOLINE IS EXTREMELY FLAMMABLE
AND IS EXPLOSIVE UNDER CERTAIN CONDITIONS.
DRAIN THE FUEL IN A WELL-VENTILATED AREA
WITH THE ENGINE STOPPED AND COOL. NEVER
SMOKE OR ALLOW FLAMES OR SPARKS IN THE
AREA DURING THIS PROCEDURE.
Remove the fuel cap and carefully turn the generator over to
pour the gasoline into an appropriate container. Reinstall the
fuel cap and start and run the engine until the engine stops,
to allow the fuel to drain from the fuel lines, carburetor, and
engine system.
Change the engine oil. Refer to Change Engine Oil.
Remove the spark plug and pour a small amount of oil into the
cylinder. Install the spark plug but do not install the spark plug
boot.
Turn the generator switch to the off “O” position.
Move the generator to the storage place.
Attach the trickle charger to the port on the control panel
and to standard AC power to keep the generator battery fully
powered for easy start after storage. Disconnect the battery
charger once the battery is fully charged (indicated by a green
light on the charger)
Cover the generator.
STORAGE