ELECTRICAL REQUIREMENTS
CAUTION: To avoid electrical shock, connect
the washer to a properly grounded electrical
receptacle. Do not use an adapter or remove third
(ground) prong.
Make certain the connection between the washer
power cord and receptacle is kept dry.
The following electrical requirements must be met:
1. The electrical supply must provide a minimum of 110 to
120 volts. With the washer operating, line voltage must
not drop below 108 volts.
IMPORTANT: Operating the pressure washer with
low line voltage may damage electrical
components and cause motor to stall.
2. This pressure washer is equipped with a Ground Fault
Circuit Interrupter in the power cord to reduce the risk
of electrical shock. However the GFCI will not protect
against all faults, short circuits, or overloads.
CAUTION: Ground Fault Circuit Interrupter (GFCI)
MUST be tested before each use of the washer.
If the results in each one of the following steps
are not as described, shut washer off immediately.
DO NOT operate until the washer has been
inspected by a qualified electrician or your dealer.
3. Plug GFCI into grounded receptacle. Connect high
pressure outlet hose and turn on water supply.
4. Press and release “RESET” button (A) to verify power
to the washer.
5. Press “TEST” button (B). Red indicator bar (C) on reset
button should appear. (Power to the washer should be
interrupted).
6. Press and release the “RESET” button. Power should
be restored to the washer.
NOTE: GFCI test instruction are also found on the front of
the GFCI.
Preparing the Washer
A
B
↑
↑
C
↑
Содержание CM-1400-0MEC
Страница 32: ...32 Operator s Manual ...