MHSC WDV500 Скачать руководство пользователя страница 20

20

78D0011

WDV Series Gas Fireplace

1.  Flexible UL1777 listed venting may be used in any venting application where rigid direct vent components 

can be used. 

all restrictions, clearances and allowances that pertain to the rigid piping apply to 

the flexible venting.

 Flex kits may not be modified. Flex kits may be 

added to the end of a vent run made of rigid vent sections using pipe 
manufacturer's  approved  flex  to  pipe  adapters.  This  may  occur 
only if doing so does not violate any of the venting length, height, 
routing, horizontal to vertical ratio requirements or clearance 
considerations detailed in this manual.

2.  The flex adapter starter kit (DVFF8A/8) is used to attach 

flex venting to the appliance starting collar. It includes 5" 
inner and 8" outer adapter rings. 

Figure 27

  The inner and outer adapter rings are required to start 

all flex runs.

   Never install damaged or torn flexible venting.

   Over  tightening  clamps  may  rip,  tear,  or  otherwise 

damage flexible venting.

   The adapter kit does not include individual pipe sec-

tions which may be purchased separately. (UL1777 
listed type venting only.)

3.  Start the flexible vent as follows:

A.  Installing the inner flex adapter and pipe. 

Figure 27

1.  Insert  the  long  side  of  the  5"  inner  ring  into 

exhaust pipe, gently tap to seat into place, and secure with 
screws.

2.  Slide the small gear clamp over the inner flexible vent pipe, 

and push out of the way.

3.  Pull and extend the inner flexible vent.
4.  Slide the inner vent onto the adapter collar, for a minimum 

1

C\v

" overlap.

5.  Locate the clamp at approximately 3/4" from the flex end and tighten.
6.  Secure the clamped inner section with three self-tapping screws, drilled 

equidistant, just above the clamp perimeter.

B.  Installing the outer flex pipe. 

Figure 27

1.  Firmly insert the 8" outer adapter ring into the outer appliance starting collar 

and secure with screws.

2.  Slide the large gear clamp over the outer flexible vent pipe, and push out 

of the way.

3.  Pull and extend the outer flexible vent.
4.  Slide the outer vent onto the appliance collar outer adapter for a minimum 

1

C\v

" overlap.

5.  Locate the clamp at approximately 3/4" from the flex end and tighten.
6.  Secure the clamped outer section with three self-tapping screws, drilled 

equidistant, just above the clamp perimeter.

C. Routing UL1777 flex pipe.

1.  Always maintain the required clearance when routing the flex vent assembly.

Flex Vent InstallatIOn

n

O

te

F l e x   v e n t   p i p e   s p a c e r s :   r e f e r   t o 
manufacturer’s  specifications  for  correct 
positioning  of  the  spacer  springs  to 
maintain  proper  distance  between  inside 
and outside pipe.

FP1972
appliance connection

UL1777
Flex Vent

Screws 

(3 places, 

equidistant just 

above gear 

clamp)

1

C\v

" Flex-

ible Pipe 
and Adapter 
Outer

DVFF8A/8 
Inner Adapter 
Outer Adapter

Appliance 
Starting Collar

Figure 27 - 
Typical Appliance Connection

FP1973
flex pipe bend

UL1777
Flex Vent

5° Radius

Figure 28 - 
Minimum Radius for Flex 
Vent Section

FP1973

Содержание WDV500

Страница 1: ...anual For assistance or additional information consult a qualified installer service agency or the gas supplier This appliance may be installed in an aftermarket permanently located manufactured home...

Страница 2: ...tion Box Wiring 25 Command Center Wall Installation 25 Wall Switch Installation 25 SCS Wiring Diagram 26 Thank you and congratulations on your purchase of a MHSC Fireplace PLEASE READ THE INSTALLATION...

Страница 3: ...by a qualified service person with glass door properly seated and sealed combustion leakage can occur CARBON MONOXIDE POISONING Early signs of carbon monoxide poisoning are similar to the flu with he...

Страница 4: ...draw all combustion air from outside of the dwelling through the vent pipe These appliances have been tested by CSA and found to comply with the established standards for VENTED GAS FIREPLACES in the...

Страница 5: ...tents for shipping damage and immediately inform your dealer if any damage is found Do not install any unit with damaged incomplete or substitute parts Check your packing list to verify that all liste...

Страница 6: ...m 5 6M 146 mm 6 152 mm 8 1 6 2 0 8 0 m m 57 6 1470 mm 4 1 1 0 4 1 m m 57 6 1470 mm 35 6 905 mm Min Rough Opening Height 780012 DVW WDV dims 4656 1172 mm 8 6QE 211 mm Required Noncombustible Material A...

Страница 7: ...on found in this manual for allowable venting configura tions These units can be installed in a bedroom Refer to the National Fuel Gas CodeANSI Z233 1 NFPA 54 current edition the Uniform Mechanical Co...

Страница 8: ...3 mantel leg 156O 256O FP2423 Side of Fire place Opening Figure 5 Mantel clearances Top View Clearances to combustibles Follow these instructions carefully to ensure safe installation Failure to follo...

Страница 9: ...h and optional fan must be done prior to final finishing to avoid costly reconstruction Only noncombustible materials i e brick tile slate steel or other materials with a UL fire rating of Zero may be...

Страница 10: ...ved by MHSC Installation other than permitted by these instruc tions Venting INSTALLATION INFORMATION Read all instructions completely and thoroughly before attempting installation Failure to do so co...

Страница 11: ...dditional pipe and elbows will be required You may use a chase with a vent termination with exposed pipe on the exterior of the house Refer to Installing A Vent System in an Outside Chase below If pip...

Страница 12: ...y above the meter regulator assembly 5 m above the meter regulator assy I Clearance to service regulator vent outlet 3 91 cm 3 91 cm J Clearance to nonmechanical air supply inlet 6 15 cm for appliance...

Страница 13: ...of the vent system 1 Determine the height of the center of the horizontal vent pipe exiting through the outer wall Using this dimen sion on the Sidewall Vent Graph below locate the point intersecting...

Страница 14: ...the flue collars to the center of the wall opening Figure 12 Step 4 Using appropriate length of pipe section s attach to fire place with three 3 screws Follow with the installation of the elbow X X Fi...

Страница 15: ...mounted to the top of the fireplace the maximum horizontal vent run before the termination or a vertical rise is 36 914 mm Figure 15 FP1176 max 90 bends Figure 14 Maximum Three 3 90 Elbows Per Install...

Страница 16: ...he collar of the fireplace or transition elbow to the face of the exterior wall See the Sidewall Venting Graph for extended horizontal run if the vertical exceeds 12 1 Establish vent hole through the...

Страница 17: ...ess Watertight Seal Around Pipe Sheet Metal Screws Wall Screws Snorkel WARNING Do not back fill around snorkel A clearance of at least 4 must be maintained between the snorkel and the soil Up to two 4...

Страница 18: ...g to the position of the flue exit Mark the center point where the vent will penetrate the ceiling Drill a small locating hole a this point Drop a plumb line from the inside of the roof to the ceiling...

Страница 19: ...combustible materials 6 Continue to add pipe sections until the height of the vent cap meets the minimum building code requirements NOTE You must increase vent height for steep roof pitches Nearby tr...

Страница 20: ...exible vent pipe and push out of the way 3 Pull and extend the inner flexible vent 4 Slide the inner vent onto the adapter collar for a minimum 1C v overlap 5 Locate the clamp at approximately 3 4 fro...

Страница 21: ...the flexible vent 5 Flexible vent spacers are to be installed at intervals prescribed by the flexible vent manufac turer and in such a way as to maintain concentric inner and outer vent spacing D Atta...

Страница 22: ...sleet When using copper of flex connectors use only fittings approved for gas connections The gas control inlet is 3 8 NPT The gas control is equipped with a captured screw type pressure test point t...

Страница 23: ...We recommend that you install a sediment trap drip leg in supply line as shown in Figure 33 Locate sediment trap drip leg where it is within reach for clean ing Install in piping system between fuel...

Страница 24: ...ectrical Wiring General 1 This fireplace is equipped with the Signature Control valve which operates on 6 volts The A C module plugs into the fireplace junction box A C power supply Four 4 AA batterie...

Страница 25: ...t extend beyond the 15 ft wire cable provided If a longer distance is required the 15 ft may be extended up to 30 ft maximum by using two 2 SCSWEK cables plugged together Route the wire from junction...

Страница 26: ...Command Center Optional Wall Switch Plug in Connector Stepper Motor to Control Board DC Power Green Ground Plug in Connector Control Board to Solenoid Gas In Gas Out Pilot Gas Tubing Valve Light 300 W...

Страница 27: ...ectly WARNING Electrical connections should only be performed by a qualified licensed electrician Main power supply must be turned off before connecting the fan to the main electrical power supply or...

Страница 28: ...ove the front floor screen frame by unfastening the four 4 screws securing the front and sides 2 Install the six 6 halogen light bulbs provided Do not touch light bulbs directly with fingers 3 Replace...

Страница 29: ...s are supplied with the 500 Series fireplaces Both bags should be used to cover the entire floor and burner Three 3 bags of glass are supplied with the 600 Series fireplaces It is not necessary to use...

Страница 30: ...phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department C Use only your finger to push in the master switch Never use tools If the switch will not f...

Страница 31: ...as go to next step 4 Press the master switch to the ON position Within eight 8 seconds it will beep once This indicates the system is ready 5 Press ON button Sparker will spark and pilot flame will li...

Страница 32: ...ut X LCD Backlight X Security Codes 16 X Countdown 6 hr Timer X Standard Thermostatic Control Mode X Smart Mode Thermostat Auto Flame Blower Modulation X Three Brightness Settings for Lights X Three S...

Страница 33: ...button One beep for RF receiver ON or two beeps for RF receiver OFF will be given as confirmation Refer to Figure 57 for location 2 After the RF receiver is on holding the OFF button on the Command C...

Страница 34: ...ff 3 Hold the OFF button anytime for three seconds or by turning off the wall switch These two commands of OFF are Memory Off the system will remember all last settings before turning off The next tim...

Страница 35: ...an extended period of time Never leave anything on top of the surface of the transmitter FP2646 TSFSC display Information Bar Touch Area Logo Bar Menus Adjustment Controls Function Areas of the LCD Di...

Страница 36: ...en and the green LED on the Command Cen ter will flash for 10 seconds WARNING Do not use two 2 or more remote control sys tems in the same area with the same privacy code setting as they will communic...

Страница 37: ...Push and hold the TIMER button for 3 seconds Or b Use the OFF down buttons to decrease the Set Time to zero Or c Slide down on the arrow buttons to exit TIMER mode and shut off the fireplace Thermosta...

Страница 38: ...off see blower On Delay and Off Delay in the next section 4 After the signal is sent the ON up and OFF down but tons become flame height controller again 5 When the fan button is flashing slide up and...

Страница 39: ...flashing slide up and down on the arrow buttons will turn the light brightness to HIGH or Off directly without pressing the light button again to confirm AUX Control Optional The AUX control function...

Страница 40: ...tteries 3 LCD display shows funny display 3 Reset the transmitter see Resetting the Transmitter section 4 Appliance does not come on 2 The transmitter did not match 1 Make sure the transmitter has wit...

Страница 41: ...year Make sure the burner porting pilot air opening and burner air opening are free of obstructions at all times Pilot Flame The flames from the pilot should be visually checked as soon as the heater...

Страница 42: ...cement glass door assemblies MUST be supplied by the fireplace manufacturer No substitute materials may be used Handle glass door with care to avoid striking or scratching it on hard objects To clean...

Страница 43: ...Battery polarity wrong LED on the Command Center does not show solid green The 5 pin connector on the AC board broken or bent AC plug is plugged to AC mains Battery voltage low Using battery Check va...

Страница 44: ...t 6 73D4521K 73D4521K 3 Glass Frame Assembly 1 78D0027K 78D1038K 4 Junction Box Assembly not shown 1 26D2128 26D2128 5 Panel Access Door 1 78D0040K 78D1046K Accessories Field Installed Options 6 Porce...

Страница 45: ...78D0011 45 WDV Series Gas Fireplace REPLACEMENT PARTS SIGNATURE COMMAND SYSTEM 780012 DVW SG parts 6 09 1 2 3 4 15 5 6 7 8a 9 14 8b 8c...

Страница 46: ...D0030 7 Injector 2 59D0062 69D0226 58D0051 20H3156 8a Burner Assembly 1 78D0033 78D0033 8b Burner Assembly 1 78D1058K 78D1058K 8c Burner Assembly 1 78D1057K 78D1057K 9 Venturi 2 69D1026 69D1026 69D102...

Страница 47: ...ones REPLACEMENT PARTS Item Description 500 Qty 600 Qty Part No 1 White Stone 1 5 5 78D0122 2 Light Gray Stone 2 5 5 78D0123 3 Dark Gray Stone 3 5 10 78D0124 4 Brown Stone 4 5 5 78D0125 5 Sand Stone 5...

Страница 48: ...48 78D0011 WDV Series Gas Fireplace HOT 1 2 3 4 5 6 9 7 8 10 730024 KHLDV vent parts VENT components REPLACEMENT PARTS...

Страница 49: ...A VC 1280 5DT VC 3 4 6 Pipe Length 58DVA 06 1208 5DT 06 3 4 9 Pipe Length 58DVA 09 1207 5DT 09 3 4 12 Pipe Length 58DVA 12 1206 5DT 12 3 4 24 Pipe Length 58DVA 24 1204 5DT 24 3 4 36 Pipe Length 58DVA...

Страница 50: ...rdance with the above provisions shall comply with NFPA 720 and ANSI UL 2034 listed and IAS certified Signage A metal or plastic identification plate shall be permanently mounted to the exterior of th...

Страница 51: ...time Warranty will also be void if the appliance is not operated and maintained according to the operating instructions supplied with the appliance and does not extend to 1 firebox burner assembly dam...

Страница 52: ...149 Cleveland Drive Paris Kentucky 40361 www mhsc com Based on CSA P 4 1 09 Efficiency Ratings Model EnerGuide Ratings Fireplace Efficiency WDV500NTSC 64 4 WDV500PTSC 67 7 WDV600NTSC 70 2 WDV600PTSC...

Отзывы: