background image

Limited Lifetime Warranty Policy

LIFETIME WARRANTY

The following components are warranted for life to the original owner, subject to proof of purchase:  
Firebox, Combustion Chamber, Heat Exchanger, Grate and Stainless Steel Burners.

FIVE YEAR WARRANTY

The following components are warranted for 5 years to the original owner, subject of proof of purchase:  
Ceramic Fiber Logs, Catalytic Filter and Aluminized Burners.

BASIC WARRANTY

MHSC warrants the components and materials in your gas appliance to be free from manufacturing and 
material defects for a period of two years from date of installation.  After installation, if any of the compo-
nents manufactured by MHSC in the appliance are found to be defective in materials or workmanship, 
MHSC will, at its option, replace or repair the defective components at no charge to the original owner.  
MHSC will also pay for reasonable labor costs incurred in replacing or repairing such components for 
a period of two years from the date of installation. Any products presented for warranty repair must be 
accompanied by a dated proof of purchase.
This Limited Warranty will be void if the appliance is not installed by a qualified installer in accordance 
with the installation instructions.  The Limited Lifetime Warranty will also be void if the appliance is not 
operated and maintained according to the operating instructions supplied with the appliance, and does 
not  extend  to  (1)  firebox/burner  assembly  damage  by  accident,  neglect,  misuse,  abuse,  alteration, 
negligence of others, including the installation thereof by unqualified installers, (2) the costs of removal, 
reinstallation or transportation of defective parts on the appliance, or (3) incidental or consequential 
damage. All service work must be performed by an authorized service representative.
This warranty is expressly in lieu of other warranties, express or implied, including the warranty of mer-
chantability of fitness for purpose and of all other obligations or liabilities. MHSC does not assume for it 
any other obligations or liability in connection with the sale or use of  the appliance. In states that do not 
allow limitations on how long an implied warranty lasts, or do not allow exclusion of indirect damages, 
those limitations of exclusions may not apply to you.  You may also have additional rights not covered 
in this Limited Warranty.
MHSC reserves the right to investigate any and all claims against the Limited Warranty and decide upon 
method of settlement.

IF WARRANTY SERVICE IS NEEDED...

1.  Contact your supplier. Make sure you have your warranty, your sales receipt and the model/serial 

number of your MHSC product.

2.  DO NOT ATTEMPT TO DO ANY SERVICE WORK YOURSELF.

MHSC

149 Cleveland Drive • Paris, Kentucky 40361

www.mhsc.com

Содержание VDY24/18D2A

Страница 1: ...mable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your bu...

Страница 2: ...4 18D3R Log Installation 14 VDY30D4 Log Installation 14 VDY30D3 VDY30D3R and 30VDYD3A Log Installation 15 VDY24 18D4 Log Installation 17 VDY30D4 Log Installation 18 DUZY 5 Log VDY24 18D5 Log Installat...

Страница 3: ...temperature and should stay away to avoid burns or clothing ignition IMPORTANT SAFETY INFORMATION 11 Young children should be carefully supervised when they are in the same room with the gas log set i...

Страница 4: ...maged immediately inform the dealer from whom you purchased the appliance Do not attempt to install any part of the appliance unless you have all parts in good condition ITEMS REQUIRED FOR INSTALLATIO...

Страница 5: ...Millivolt Thermopile 50 000 VDY30NMP Yes Manual Thermocouple 65 000 VDY30NVP Yes Millivolt Thermopile 65 000 Model Number Pilot Control Type Gas Rate Min BTU Hr VDY24 18PMP Yes Manual Thermocouple 50...

Страница 6: ...Damper Stop Installation Manual Series Millivolt Series PRODUCT FEATURES SPECIFICATIONS Figure 1 Minimum Hearth Dimensions Minimum Opening Area of Chimney Damper for Venting FOR MASSACHUSETTS RESIDEN...

Страница 7: ...h as refractory brick may be used to line the floor of the fireplace in order to raise the height of the gas log set in relation to a restrictive barrier If the unit is raised the minimum height dimen...

Страница 8: ...grate correctly mark the hole positions on the fireplace firebox floor Drill two 2 5 32 diameter holes approximately 11 2 deep 3 Anchor the grate to the fireplace firebox floor using the screws provid...

Страница 9: ...ocations that the Pressure Tapping Point May be Installed NOTICE A qualified gas appliance installer must connect the appliance to the gas supply Consult all local codes before installation caution Us...

Страница 10: ...gauge over test point Use test point labeled OUT After taking pressure reading be sure and turn captured screw clockwise firmly to re seal Do not over torque Check for gas leaks Test Port Out Figure 7...

Страница 11: ...ated A Complete Millivolt System Check A Reading contacts CLOSED Control Knob ON Main burner should be come ON a If the reading is more than 100 millivolts and the automatic valve still does not come...

Страница 12: ...til touching the rear log 1 Visually check to verify the log is resting on the grate and control cover See Figure 11 3 Install the left log 3 with its bottom groove resting on the right side of the gr...

Страница 13: ...s resting on the grate and control cover See Figure 16 3 Install the left log 3 with its bottom groove resting on the right side of the grate bar Slide the log back until touching the rear log 1 Visua...

Страница 14: ...on right front of grate bar lining up cutout in bottom of log with grate bar Make sure Log 3 touches Log 1 See Figure 22 4 Place back end Top Middle Log 4 on Log 1 Press the side of Log 4 up against r...

Страница 15: ...hes on Log 2 and Log 4 See Figure 25 Figure 24 Placing Top Right Log 5 Top Right Log 5 Figure 25 Placing Top Left Log 6 Top Left Log 6 Figure 26 Base Locator Pins Control Cover Figure 27 Placing Rear...

Страница 16: ...Press the side of Log 4 up against raised area of Log 1 Line up notch in front end of 4 with grate bar See Figure 30 5 Rest Top Right Log 5 on Log 3 See Figure 31 6 Line up Top Left Log 6 with notche...

Страница 17: ...Log 4 across middle of Bottom Front and Back Logs See Figure 37 5 Place Left Top Crossover Log 5 up against Left Top Log See Figure 38 6 Rest Right Top Log 6 on Center Crossover Log and front of grate...

Страница 18: ...ottom Front and Back Logs See Figure 44 5 Place Left Top Crossover Log 5 up against Left Top Log See Figure 45 6 Rest Right Top Log 6 on Center Crossover Log and front of grate See Figure 46 7 Place S...

Страница 19: ...e Figure 50 3 Place Bottom Left Log 3 on left side of grate See Figure 51 4 Place one end of Middle Left Log 4 on Bottom Left Log Rest other end of Middle Left Log 4 behind Middle Right Log See Figure...

Страница 20: ...Front Middle Log 8 First Prong Second Prong LOG PLACEMENT DUZY5 LOG VDY24 18D5 Installation SEQUENCE continued 5 Place Middle Right Log 5 on top of Bottom Right Log See Figure 53 6 Rest Top Right Log...

Страница 21: ...ate in front of back log See Figure 59 3 Place Bottom Left Log 3 on left side of grate in front of back log See Figure 60 4 Place Middle Left Log 4 on top of bottom left log See Figure 61 Figure 58 Pl...

Страница 22: ...ck log See Figure 63 7 Place Top Left Log 7 on bottom left log and middle left log See Figure 64 8 Place Middle Front Log 8 between second and third grate bars See Figure 65 Figure 62 Placing Middle R...

Страница 23: ...ogs per the cleaning and servicing section of the manual FIREPLACE DRAFT TEST FIREPLACE DRAFT TEST METHOD To determine if your fireplace is drafting properly turn the log set on After the log set has...

Страница 24: ...volt Control with Pilot Only Pilot Flame Appearance The pilot flame must always be present when appliance is in operation It should touch the thermocouple or thermopile body Initial Startup During man...

Страница 25: ...gas control knob counterclockwise to ON OPERATING INSTRUCTIONS SAFETY INSTRUCTION FOR MANUAL AND Millivolt CONTROL WITH PILOT Figure 69 Control Knob Figure 70 Manual Pilot for your safety read before...

Страница 26: ...b in for a further 60 seconds to prevent the flame detector from shut ting off the gas while the probe is warming up Release the control knob 9 Turn gas control knob counterclockwise to the ON positio...

Страница 27: ...nside the fireplace with 2 clearance to the side wall installing remote receiver Connect wires according to remote receiver instructions The female terminals should be connected to factory attached ma...

Страница 28: ...s clean will result in sooting and poor combustion If embers rock wool have turned a rust color and become brittle remove old embers rock wool from log set Replace with new rock wool Rock wool can be...

Страница 29: ...2D0400 32D0410 2 Right Log 1 32D0401 32D0411 3 Left Log 1 32D0402 32D0412 4 Top Log 1 32D0403 32D0413 Item Description Qty VDY24 18D3R VDY30D3R 1 Rear Log 1 32D2118 32D2124 2 Front Left Log 1 32D2117...

Страница 30: ...8D4 VDY30D4 1 Back Log 1 32D3101 32D3111 2 Bottom Front Log 1 32D3102 32D3112 3 Top Left Log 1 32D3103 32D3113 4 Center Crossover Log 1 32D3104 32D3114 5 Left Top Crossover Log 1 32D3105 32D3115 6 Rig...

Страница 31: ...2D3126 7 Top Left Log 1 32D3127 8 Front Middle Log 1 32D3128 1 2 3 4 5 6 8 7 Duzy V Logs Series Illustrated parts list Item Description Qty VDY30D5 1 Back Log 1 32D3131 2 Bottom Right Log 1 32D3132 3...

Страница 32: ...Main Injector 32D0090 32D0113 32D0090 32D0117 2 Control Knob 27D0602 27D0602 18D0603 18D0603 3 Manual Control Valve with Pilot 27D8951 27D8951 N A N A 4 Millivolt Control Valve with Pilot N A N A 27D...

Страница 33: ...pliance shuts off dur ing use 1 Low line pressure 2 Pilot is partially clogged 3 Defective Thermopile 1 Locate and correct all leaks 2 Replace control valve Gas odor even when control knob is in OFF p...

Страница 34: ...er orifice is clogged or dam aged 2 Burner is damaged 3 Gas regulator defective 1 Clean burner or replace burner orifice 2 Replace burner 3 Replace gas regulator Logs appear to smoke after initial ope...

Страница 35: ...e requirements provided however that during said thirty 30 day period a battery operated carbon monoxide detector with an alarm shall be installed Massachusetts Residents Only Please read and follow t...

Страница 36: ...lso be void if the appliance is not operated and maintained according to the operating instructions supplied with the appliance and does not extend to 1 firebox burner assembly damage by accident negl...

Отзывы: