86D0024
29
LG551
In normal operation at full rate after 15 minutes, the following lame appearances
should be observed:
Figure 33 - Correct Burner Flame Appearance
Burner will have a random pattern of yellow lames as shown in
Figure 33.
There should be glow-
ing embers on the front burner.
Note: The front lames and embers will be an opaque orange
color during the burn off time.
OPERATING INSTRuCTIONS
Avoid any drafts that alter burner lame patterns.
Do not allow fans to blow directly into the
ireplace. Do not place a blower inside the burn area of the irebox. Ceiling fans may create drafts
that alter lame patterns. Sooting and improper burning will result.
During manufacturing, fabricating and shipping, various components of this appliance are treated
with certain oils, ilms or bonding agents. These chemicals are not harmful, but may produce
annoying smoke and smells as they are burned off during the initial operation of the appliance,
possibly causing headaches or eye or lung irritation.
This is a normal and temporary occurrence.
The initial break-in operation should last four hours with the burner at the highest setting. Provide
maximum ventilation by opening windows or doors to allow odors to dissipate. Any odors remain
-
ing after this initial break-in will be slight and will disappear with continued use.
This appliance must not be used with glass doors in the closed position. This can lead to pilot out-
ages and severe sooting outside the ireplace.
Refer to Page 10, Figure 3.
CHECKING THE BURNER FLAME