86D0024
17
Damper Stop
Damper
FP2005
BEFORE INSTALLING ThE APPLIANCE:
• Turn off gas supply to ireplace or irebox.
• Have the ireplace loor and chimney professionally cleaned to remove ashes, soot, creosote or other obstruc
-
tions. Have this cleaning performed annually after installation.
• Seal any fresh air vents or ash clean-out doors located on loor or wall of ireplace. If not, drafting may cause
pilot outage or sooting. Use a heat-resistant
sealant.
Install and operate the appliance as directed
in this manual.
DAMPER STOP INSTALLATION:
A damper stop must be provided with the unit.
Contact your dealer to obtain one. The damper
stop must be installed as shown in
Figure 12
to
prevent full closure of the ireplace damper blade
and provide a minimum 29 square inch lue opening.
Figure 12 - Damper Stop Installation.
FIREPLACE PREPARATION
BEFORE FULLY INSTALLING THE UNIT:
• Turn
OFF
the gas supply to the ireplace or irebox.
• Seal any fresh air vents and/or ash clean-out doors located on the loor or wall of the ireplace. If left unsealed,
drafting may cause pilot outage or sooting. Use a heat resistant sealant.
Do not seal the chimney lue
damper.
INSTALLING vENTED APPLICATIONS
Manual and Millivolt controlled gas logs may be installed as a vented decorative log set in compliance with ANSI
Z21.60 and National Fuel Gas Code, Section 6.6.
Since, the gas logs are operated with the damper open,
non-combustible material and minimum mantel requirements do not apply.
W
A
R
N
IN
G
This appliance is for installation only in a solid fuel burning ireplace (masonry ireplace
or manufactured ireplace) with a working lue and constructed of noncombustible
material.
Exception:
DO NOT install this appliance in a factory-built ireplace that includes
instructions stating that it has not been tested or should not be used with unvented
gas logs. This log set may be installed as a vented log set.
W
A
R
N
IN
G
Before installing in a solid fuel burning
ireplace, The chimney lue and irebox must
be cleaned of soot, creosote, ashes and loose
paint by a qualiied chimney cleaner.
W
A
R
N
IN
G
The ireplace and gas logs function as a system. If the ireplace is spilling into the room
(check with a match or a smoke stick), reposition the damper clamp until a positive
draft is obtained by opening the damper. If negative pressure in home prevents having
a positive draft, contact your dealer for assistance.