No.   DESCRIPTION

1

CONTROL PANEL 

1249109

2

GASKET 61 x 48 x 3

8566000

3

REDUCING BUSH 1”1/2 x 3/4

8588806

4

THERMOSTAT POCKET

1764200

5

RIGHT CAST IRON CLEANING 

ACCESS COVER PLATE

0633700

5

LEFT CAST IRON CLEANING

ACCESS COVER PLATE

0633800

6

CERAMIC FIBRE PANEL FOR ITEM 5

0666700

7

CAST IRON CLEANING 

ACCESS COVER PLATE

0633600

8

CERAMIC FIBRE PANEL FOR ITEM 7

0666600

9

CONNECTION PIECE

8589402

10

GAS VALVE ROBERTSHAW

0656002

11

ELBOW PIPE

0653310

12

GAS DISTRIBUTION PIPE

0654100

13

CAST IRON FRONT PLATE

0633200

14

CERAMIC FIBRE FRONT PANEL

1266001

15

FIXING BRACKET

0648600

16

FRONT GAS BURNER 

1255210 1255210 1255212 1255212 1255214 1255214 1255216 1255216

REAR GAS BURNER

1255209 1255210 1255210 1255212 1255212 1255214 1255214 1255216

17

PILOT BURNER BRAHMA BPEMC70

0660101

18

BLIND PLUG 1/2”

8589604

19

REDUCING BUSH 1" 1/2x1/2

8588801

20

FRONT SECTION

1230000

21

RIGHT SUPPORT FOOT

0634304

21

LEFT SUPPORT FOOT

0634305

22

PIPE-FIXING BRACKET

0648000

23

GAS FEED PIPE

1251509 1251510 1251511 1251512 1251513 1251514 1251515 1251516

24

INTERMEDIATE SECTION

1230500

25

TIE RODS M14 (SET)

2384009 2384010 2384011 2384012 2384013 2384014 2384015 2384016

26

RIGHT SUPPORT FOOT

0634304

26

LEFT SUPPORT FOOT

0634305

27

DISTRIBUTION PIPE

0651501

28

REAR SECTION

1230900

29

RUBBER GASKET 155x105x70

2366200

30

FLANGE 2" 1/2

8591853

31

REAR CAST IRON PLATE

0633200

32

REAR CERAMIC FIBRE PANEL  

1266001

33

REAR CAST IRON CLEANING 

ACCESS COVER PLATE

0633900

34

REAR CER. FIBRE PANEL

FOR ITEM 33

0666800

36

FLUE HOOD

1246159 1246160 1246161 1246162 1246163 12460164 1246165 1246166

37

DRAUGHT DIVERTER

1246059 1246060 1246061 1246062 1246063 1246064 1246065 1246066

38

THERMOSTAT POCKET

8564200

39

ELBOW PIPE

1251500

40

FRONT/REAR APRON

1245101

41

SIDE PANELS FIXING BRACKET

1245151

42

MOTOR BRACKET

1248050

44

JOINT

1277000

45

DAMPER MOTOR

1272559

6

Содержание REGENCY 4 MODULEK Series

Страница 1: ...R E G E N C Y 4 R E G E N C Y 4 INSTALLATION AND SERVICING INSTRUCTIONS FROM 9 TO 16 SECTION BOILERS COD 1274061 M O D U L E K M O D U L E K...

Страница 2: ......

Страница 3: ...table for heating large dwellings commercial or industrial buildings They are designed for use on pumped circulation systems and if used for hot water production calorifiers indirect cylinders plate h...

Страница 4: ...ilers of rated inputs between 60 kW and 2 MW IGE UP 2 Gas installation pipework boosters and compressors on industrial and commercial premises CIBSE Guide Reference sections B7 B11 and B13 British Gas...

Страница 5: ...2 4 Air supply 2 4 1 Air supply by natural ventilation 2 4 2 Air supply by mechanical ventilation 2 5 Gas connection 2 6 Water connection 2 6 1 System water treatment 2 7 Flue hood assembly 2 8 Draug...

Страница 6: ......

Страница 7: ...d off the damper shuts down the chimney avoiding heat losses through the chimney with one firing burner the damper partially closes to avoid eccessive secondary air from passing through the boiler wit...

Страница 8: ...t 300 R 1 1 4 160 710 75 1450 210 Regency 4 186 11 sect 300 R 1 1 4 260 860 75 1650 310 Regency 4 203 12 sect 300 R 1 1 4 160 810 75 1650 210 Regency 4 220 13 sect 300 R 1 1 4 260 960 75 1850 310 Rege...

Страница 9: ...20 20 20 20 20 20 pressure GPL G30 mbar 30 30 30 30 30 30 30 30 GPL G31 mbar 37 37 37 37 37 37 37 37 Burner Natural gas mbar 11 5 11 5 11 5 11 5 11 5 11 5 11 5 11 5 pressure GPL G30 mbar 29 0 29 0 29...

Страница 10: ...rmostat Overrun relay High limit thermostats Thermometer External flue hood Unassembled casing Contacts arrangement for external controls Option to operate in the two stage or in the on off mode Optio...

Страница 11: ...26X N I4 0Y I4 6Xe7 I4 6K f V4 6X h V 1 N L V 1 3 1 1 3 I4 0M I K I 6K eJ I4 Kh V4 3 1 V L V L N N L 0M V V4 6KO 1 I 6Kg V N X N 1 5 1 V4 I V 6Xf V 3 1 3 O 3 L I4 V4 V4 K eJ V4 N L V4 X L N 1 I I I 6K...

Страница 12: ...604 19 REDUCING BUSH 1 1 2x1 2 8588801 20 FRONT SECTION 1230000 21 RIGHT SUPPORT FOOT 0634304 21 LEFT SUPPORT FOOT 0634305 22 PIPE FIXING BRACKET 0648000 23 GAS FEED PIPE 1251509 1251510 1251511 12515...

Страница 13: ...SETBUTTON FOR RESETTING THE FRONT IONISATION CONTROL 14 REAR BURNER SWITCH FOR ON OFF OPERATION OF REAR BURNER 15 IONISATIONRESETBUTTON FOR RESETTING THE REAR IONISATION CONTROL 16 PUMP OVERRUN CONTRO...

Страница 14: ...REGENCY 4 MODULEK 255 750 mm 750 mm REGENCY 4 MODULEK 272 800 mm 800 mm The boiler is delivered as a consignment of four packages It is supplied complete with a draught diverter which must be fitted...

Страница 15: ...with a wire mesh to pro tect against blockage The terminal should not be sited adjacent to any opening window air vent or other ventilation opening and should be situated at least 1 m above the roof s...

Страница 16: ...r Regency 4 Modulek 237 Low Level 1615 cm2 per boiler High level 856 cm2 per boiler Regency 4 Modulek 255 Low Level 1712 cm2 per boiler High level 907 cm2 per boiler Regency 4 Modulek 272 Low Level 18...

Страница 17: ...the circulating water particularly where the system type is open vented The fill water will almost always produce a scale deposit on the waterways of the boiler This deposit will reduce the heat tran...

Страница 18: ...e aprons 6 to the front and rear plates using the stud and nut fi xings both aprons are delivered with the casing in a separate carton Insert the two multi bar burners into the combustion chamber and...

Страница 19: ...able bush pro vided and then insert it through the slots of same bracket screw the motor cable connector into the socket fixed on the bottom of control panel BEWARE the motor has been already wired an...

Страница 20: ...ep to terminals 48 49 and the switch of the 2nd step to terminals 50 51 The overrun relay fitted avoids boiler nuisance trip of the limit safety thermostat when the cir culating pump is stopped with a...

Страница 21: ...ELECTRICAL DIAGRAM REGENCY 4 152 272 9 16 SECTION BOILERS 15...

Страница 22: ...16...

Страница 23: ...17...

Страница 24: ...18...

Страница 25: ...19...

Страница 26: ...20...

Страница 27: ...21...

Страница 28: ...internal fold to the brackets 6 secure the link side panel to the front fixing bracket 5 using the screws F 4 2 x 9 5 pro vided secure the right side panel to the front fixing bracket 5 using the two...

Страница 29: ...e that gas system is completely purged of air pilot coil of front gas control valve is energised 24Vcc Should the front pilot burner light and ignition electrode should continue to spark and if after...

Страница 30: ...he main rear burner shall light Attach manometer to front burner pressure test point and turn on gas supply Turn on the front switch When front burner is fully ignited and stable adjust gas pressure o...

Страница 31: ...for obstruction To clean the boiler outer case use a damp dusting cloth only Warning always turn off the electrical supply before proceeding Do not use detergents or solvents To remove particularly re...

Страница 32: ......