Post-purge time TL
max
0
– 10
5
Min
9542
Post-purge time min
0
– 51
5
S
9544
Post-purge time 2
0.2
– 51
0.2
S
9545
Post-purge in lockout
pos
Off, On
Off
9551
Required speed stop
max
0
– 2000
300
Min
-1
9610
Capacity
Up to 70kW, Up to 120kW, Above
120kW
Up to 70kW
9611
LP configuration
LP mode 1, LP mode 2, LP mode 3,
LP mode 4, LP mode 5
LP mode 1
9612
GP configuration
GP not connected, GP connected
GP not
connected
9613
Home run mode
Startup with home run, startup
without home run
Startup with
home run
9614
Post-purging level
Run, Pre-purge
Run
9615
Forced pre-purging on
error
Off,On
On
9616
Max speed
0
– 10000
10000
Min
-1
9617
Hall sensor pulse/rev
0
– 6
2
9618
Ion. Curr. Level extran
light
0
– 100
0.61
µA
9619
Ion. Curr. Level flame
exting
0
– 100
0.78
µA
9626
Fan output/speed
slope
-1000
– 1000
0
9627
Fan output/speed Y-
section
-1500
– 1500
0
9630
Speed Kp
0
– 15.9375
1.125
9631
Speed Tn
0
– 600
8
S
9632
Speed Tv
0
– 1.75
0
S
9650
Chimney drying
Off, Temporarily, Permanently
Off
9651
Req. speed chimney
drying
0
– 10000
500
Min
-1
9652
Duration chimney
drying
10
– 1440
10
Min.