MGL Avionics ASX-1 Скачать руководство пользователя страница 9

ASX-1 Operating Manual

Page 9

7 Loading factory default settings

Pressing and holding the F1 and F2 simultaneously on power up will cause the ASX-1 to load preprogrammed factory 
default settings. The following screen will be displayed:

8 Operating the alarms

If the alarm is activated, the corresponding item on the display will flash. At the same time the externally available alarm 
switch   will   close.   The   switch   will   remain   closed   until   any   button   is   pressed   to   acknowledge   the   alarm   or   until   the 
condition(s) that activated the alarm no longer exist. The alarm output can be used to switch an external alarm indicator. 
The external alarm switch is an open collector transistor switch to ground with a maximum rating of 0.5A DC. It is possible 
to wire the alarm contacts of several Stratomaster instruments in parallel should this be desired. To avoid false activation 
of the alarms, the alarm function is only active 10 seconds after the instrument has powered up.

9 Cleaning

The unit should not be cleaned with any abrasive substances. The screen is very sensitive to certain cleaning materials 
and should only be cleaned using a clean, damp cloth. 

10 ASX-1 Specifications

Operating Temperature Range

-10ºC to 50ºC (14ºF to 122ºF)

Storage Temperature Range

-20ºC to 80ºC (-4ºF to 176ºF)

Humidity

<85% non-condensing

Power Supply

8 to 30Vdc SMPS (switch mode power supply) with built in 33V over voltage 
and reverse voltage protection

Current Consumption

Approx. 50mA @ 13.8V (backlight on) 16mA @13.8V (backlight off)

Display

114x64 graphic LCD display. Contrast and backlight is user configurable, 
green/yellow backlight

ADC

12bit over sampled successive approximation

Dimensions

see Infinity series dimensional drawing

Enclosure

2 1/4” ABS, black in color, front or rear mounting

Weight

Approx. 120 grams

Alarm contact current rating

Open collector transistor switch to ground. Maximum rating 0.5A DC

Non-volatile memory storage

100000 write cycles

Altimeter range

-700ft to 30 000ft (-213m to 9144m)

Altimeter resolution

1ft/1m

Measurement accuracy

+/- 1mB, +/- 30ft at sea level

Airspeed range

16mph to 250mph

Airspeed resolution

1 mph

Measurement accuracy

+/-1% at 85mph nominal

Airtalk protocol

19200 baud, 8 data bits, no parity, 1 stop bit (TTL voltage levels)

Warning:

  The ASX-1 is not waterproof, serious damage could occur if the unit is exposed to 

water and/or spray jets.

Содержание ASX-1

Страница 1: ...hat stores the duration of each of the last 24 flights an air distance trip counter and a current flight timer The ASX 1 is the ideal instrument for installations where panel space is limited 1 Featur...

Страница 2: ...ess the rotary control during normal mode to access the menu system Rotate anti clockwise for up down menu scrolling During normal mode rotating the rotary control will adjust the local pressure setti...

Страница 3: ...ight time is automatically reset when a new flight is started The air distance trip counter can still be reset manually even if the pilot selects the automatic resetting of the air distance trip count...

Страница 4: ...uration of 60 seconds or more a flight is started with a logbook entry The flight ends if airspeed falls below the preset flight take off airspeed for 30 continuous seconds During a flight the logbook...

Страница 5: ...lect if you would like the hour to be displayed in decimal fractions 0 99 or minutes 0 59 This setting influences the current flight time display and the flight log Select whether you want the ASX 1 t...

Страница 6: ...to measure the zero airspeed reading of the airspeed sensor and set a calibration value internally for this This is equivalent to some mechanical airspeed indicators that have an adjustment to set the...

Страница 7: ...ion that suffers from strong turbulence at the pitot tube select slow If you have a very clean airflow in front of the pilot tube you can select fast which will give you a faster response to airspeed...

Страница 8: ...ted for air density As air density decreases with altitude an airspeed indicator will under read at altitude This error can be appreciable for example at an altitude of 5 000 ft 1 524 m errors of 5 to...

Страница 9: ...rtain cleaning materials and should only be cleaned using a clean damp cloth 10 ASX 1 Specifications Operating Temperature Range 10 C to 50 C 14 F to 122 F Storage Temperature Range 20 C to 80 C 4 F t...

Страница 10: ...r pod or panel if you do not use a static port Any build up of a pressure differential due to ram air or suction can lead to large errors of the indicated airspeed Static ports are usually mounted at...

Страница 11: ...d as the aircraft if flying Small errors related to location may be calibrated out using the ASI calibration function The use of an external 1A fuse is recommended Connect the supply terminals to your...

Страница 12: ...valid and relevant pilot s license This person has to make themselves familiar with the operation of this instrument and the effect of any possible failure or malfunction Under no circumstances does t...

Отзывы: