3.1 Start/Stop Flight display

    

Press the F1 key during the normal display mode to manually start/stop a flight. This key is only active if the ASX-1 is 
setup to select the manual flight option under the log book setup menu.

3.2 Flight time and air distance display

This display can be accessed by pressing the F2 key during the normal display mode. Use the up/down keys or the rotary 
control to select “reset air dist” to reset the air distance counter. The flight time is automatically reset when a new flight is 
started. The air distance trip counter can still be reset manually even if the pilot selects the automatic resetting of the air 
distance trip counter.

      

4 Menu System

Pressing the rotary control button during the normal display mode will cause the ASX-1 to enter the menu system. Use 
the up/ down keys or the rotary control to navigate through the menu system. 

       

       

    

           

    

       

           

           

           

Note:

 The air distance trip counter measures distance flown through the air. This is not the same as 

distance   flown   over   the   ground   unless   you   are   flying   at   sea   level   at   zero   wind   speed.   The  air 
distance shown is subject to under reading at altitude due to decreased air density.

Содержание ASX-1

Страница 1: ...hat stores the duration of each of the last 24 flights an air distance trip counter and a current flight timer The ASX 1 is the ideal instrument for installations where panel space is limited 1 Featur...

Страница 2: ...ess the rotary control during normal mode to access the menu system Rotate anti clockwise for up down menu scrolling During normal mode rotating the rotary control will adjust the local pressure setti...

Страница 3: ...ight time is automatically reset when a new flight is started The air distance trip counter can still be reset manually even if the pilot selects the automatic resetting of the air distance trip count...

Страница 4: ...uration of 60 seconds or more a flight is started with a logbook entry The flight ends if airspeed falls below the preset flight take off airspeed for 30 continuous seconds During a flight the logbook...

Страница 5: ...lect if you would like the hour to be displayed in decimal fractions 0 99 or minutes 0 59 This setting influences the current flight time display and the flight log Select whether you want the ASX 1 t...

Страница 6: ...to measure the zero airspeed reading of the airspeed sensor and set a calibration value internally for this This is equivalent to some mechanical airspeed indicators that have an adjustment to set the...

Страница 7: ...ion that suffers from strong turbulence at the pitot tube select slow If you have a very clean airflow in front of the pilot tube you can select fast which will give you a faster response to airspeed...

Страница 8: ...ted for air density As air density decreases with altitude an airspeed indicator will under read at altitude This error can be appreciable for example at an altitude of 5 000 ft 1 524 m errors of 5 to...

Страница 9: ...rtain cleaning materials and should only be cleaned using a clean damp cloth 10 ASX 1 Specifications Operating Temperature Range 10 C to 50 C 14 F to 122 F Storage Temperature Range 20 C to 80 C 4 F t...

Страница 10: ...r pod or panel if you do not use a static port Any build up of a pressure differential due to ram air or suction can lead to large errors of the indicated airspeed Static ports are usually mounted at...

Страница 11: ...d as the aircraft if flying Small errors related to location may be calibrated out using the ASI calibration function The use of an external 1A fuse is recommended Connect the supply terminals to your...

Страница 12: ...valid and relevant pilot s license This person has to make themselves familiar with the operation of this instrument and the effect of any possible failure or malfunction Under no circumstances does t...

Отзывы: