Installation
Assembly
Assembly and installation must only be carried out by qualified staff
Before you begin:
-Ensure correct power supply voltage.
-Check an efficient ground system is present
Cable passage hole for heating element current detection.
Power unit
Reserve in the electrical cabinet 110mm on a DIN rail EN
50022- 50035 and insert the unit in it.
Display unit
Cut out the panel based on the measurements given, insert
the module and tighten from behind using the screw
fastening clips supplied.
An adapter for DIN rail installation EN 50022-50035 can be
supplied on request, in this case reserve 60mm next to the
power unit.
Power transformer
Positioning of the transformer is constraint-free, but you are
advised to assess it based on the cable length. It is good practice
to optimise the length of the cable, especially the part connected
to the secondary.
If possible, avoid dividing the cable into sections using terminals.
The dimensions of the transformer are variable and depend on the
application. See chapter for calculation.
4
8.8.8
8.8
TD
TO
TR
≡
TR-EVO
48 mm
9
6
m
m
45 mm
9
2
m
m
DRILLING
92 X 45
1 2 3 4 5 6
15 14 13 12 11 10 9 8 7
106 mm
9
0
m
m