MG TR-EVO Скачать руководство пользователя страница 21

Warranty

M.G. industry srl

  guarantees its product, identified via a manufacturing code or by a brand 

name, is free of material and manufacturing defects which would mean it does not conform to the 
technical specifications indicated, and is committed for 12 months, starting from delivery date, to 
repairing or replacing the faulty part, component, equipment or part of it free of charge, returned 
to the manufacturer, unless the fault or malfunction is due to:
a) poor installation, even if conducted by qualified staff;
b) improper use of the product, due to lack of expertise, negligence or non-compliance with the 
operating instructions;
c) lack of or poor maintenance, even if carried out by qualified staff;
d) repairs or changes made by the purchaser on his own initiative;
e)   irregular   voltage   conveyance   of   the   power   lines,   insufficient   capacity   and/or   abnormal 
electrical installations;
f) abrasive or corrosive action of the physical or chemical agents;
g) poor or non-operation of the software or hardware or loss of data, registered by the purchaser, 
following storms, lightening, high temperatures or variation of electrical voltage, earthquakes, 
fires, etc.
The warranty also excludes all parts subject to normal wear, for which replacement is planned as 
ordinary maintenance.
In all cases in which the warranty remains excluded, as above given for example purposes, no 
compensation is due from M.G. srl for any damage caused to the purchaser and/or third parties 
due to use or poor operation of the product or for the period during which the system should 
remain inactive, as a result of faults and/or repairs, even if within the terms of warranty.
No indemnity will however be recognized for the purchaser or third parties for consequences 
deriving from no or improper functioning of the software and/or hardware, herein including direct 
and indirect damage.
For repairs or replacement, this part, component, equipment or part of it, must be sent/delivered 
to the manufacturer's plant on receipt of written authorization from M.G. industry srl and will not 
involve renewal of the period of warrant for the entire device, but only the relevant part.
The manufacturer reserves the right to make changes, at any time, to the equipment built and/or 
sold without being in any way obliged to make the same changes to the equipment previously 
built and/or sold.

 19     

Содержание TR-EVO

Страница 1: ...TR EVO 220 240Vac INSTRUCTIONS FOR USE MG MGINDUSTRY srl Via Casa Celeste 14 36014 Santorso VI Italy E mail mg mgonline it Draft 2 13 02 2020 EN...

Страница 2: ...Warranty 19 Appendix 20 System dimensioning 20 Editor s notes This manual contains confidential information All rights reserved The manufacturer reserves the right to make changes or improvements wit...

Страница 3: ...ctional and compact this system is the strength of heat sealing processes including with hot air temperature control hot cutting etc Warnings ATTENTION for correct use of your temperature controller i...

Страница 4: ...ltage contact Temperature adjustment range 30 to 500 degree with lockable limits Unit operational temperature 0 to 50 degree Adjustments and configuration through integrated keypad and numeric display...

Страница 5: ...d element during the tuning phase the temperature can be found on measurement Based on these calculations the power necessary to bring or maintain the temperature set is calculated and a solid state s...

Страница 6: ...fastening clips supplied An adapter for DIN rail installation EN 50022 50035 can be supplied on request in this case reserve 60mm next to the power unit Power transformer Positioning of the transforme...

Страница 7: ...connections can cause problems Warning remember that during heating for example of a bar elongation and shortening caused by heating and cooling of the heating element must not affect the quality of...

Страница 8: ...e power supply of the device between 220 and 240 Vac 15 15 This line is protected inside the device with a 100mA fuse Connect mains neutral to terminal 5 shared with the neutral of power output Connec...

Страница 9: ...e a voltage between 12 Vac and 24Vac or from 12Vdc to 30Vdc by applying the positive to terminal 11 and 13 and the negative to terminal 12 In the presence of the START signal terminal 11 the heating e...

Страница 10: ...side of this paragraph how to make two passages Do reference to the section Transformer sizing for more information User interface connector The power unit should be connected to the display user inte...

Страница 11: ...S500 it is not an alloy but is used to adapt the air heater to the temperature controller Nickrome40 and Alloy20 are registered trademarks of the relevant manufacturer Transformer dimensioning Conside...

Страница 12: ...are used to calculate the secondary voltage Vs of the transformer in volts according to the formula Vs Pr The power of the transformer Pt must be calculated in Watts using the formula Pt Pr 1 1 where...

Страница 13: ...ies If the device detects anomalies in its operation it blocks and signals the type of anomaly on the display and activates a signal output In standby mode the equipment does not adjust the temperatur...

Страница 14: ...ture control at the pre heating temperature 2 and the start input allows you to activate the temperature control at the heating temperature 4 The start input has priority over the pre heating input On...

Страница 15: ...ivated at the right moment 5 Heating the temperature is brought to the work value for the time selected on the relevant timer 6 Cooling the heating element is no longer powered and when the temperatur...

Страница 16: ...During the tuning procedure an error highlights in the transformer connection During the first tuning operation after installation it may also indicate improper connections 6 Too high current reading...

Страница 17: ...directly using the associated keys With serial bus connection In this mode configuration is executed using the commands sent via the EIA TIA485 interface by a PLC or PC remote device The communication...

Страница 18: ...nd keep pressed the key until the counter on the second line reaches zero Warning The counter may continue to restart even if you press and hold the button signalling that the conditions are not right...

Страница 19: ...measurement C degrees Centigrade F degrees Fahrenheit code 16 Analogue input voltage selection Allows you to adjust the temperature with a potentiometer connected to the device or with an external 0 1...

Страница 20: ...vo devices On code 23 the display shows rEt and allows you to exit parameter programming status by pressing the key The key returns you to the beginning parameter 11 display Maintenance ATTENTION befo...

Страница 21: ...g high temperatures or variation of electrical voltage earthquakes fires etc The warranty also excludes all parts subject to normal wear for which replacement is planned as ordinary maintenance In all...

Страница 22: ...20...

Страница 23: ...Maximum power available Watt Material to seal Name Thickness m Layers q q q q 2 layers 2 layers 3 layers 4 layers Frequency Speed max n strikes min Sealing speed m sec Sealing time sec Choice of heati...

Страница 24: ...pplication diagram Cooling q no q air q water Timed management of sealing no on machine on temperature controller Desired user interface q numerical display and potentiometer q dnumerical disply and a...

Отзывы: