18 – FS 345 Door Controls / Rev. A 0.0
7.1 Overview of the LCD monitor
AUTOMATIC
O
STANDBY
A
B
C
D
E
F
G
H
Key:
A:
Mode of operation / DIAGNOSIS info
B:
Parameters / DIAGNOSIS info
C
Button (+)
D:
Button (-)
E
Button (P)
F
Value / status
G
Value / status
H
Jumper
7.2 LCD monitor, modes of operation
The control has four modes of operation with the LCD moni-
tor:
1. AUTOMATIC
2. ADJUSTMENT
3. INPUT
4. DIAGNOSIS
If jumper H is removed, the (+) button, the (-) button and the
(P) button have no function.
The display still functions.
After switching the control on, it is in INITIALISATION mode.
The display shows INIT PHASE and the control is not yet ready
for use. This phase lasts approx. 5 seconds.
7. Programming with the LCD monitor
6.3 FT limit switch settings
2. Limit switch OPEN
green
3. Safety limit switch OPEN
red
4. Safety limit switch CLOSED
red
5. Limit switch CLOSED
white
6. Auxiliary limit switch CLOSED white
NOTICE
Damage to property or irreparable damage due to
incorrect adjustment!
The door can be damaged if it is driven beyond the end
position while adjustments are being made.
1.
Select the ADJUSTMENT menu on the display
2.
Move the door to the desired CLOSED position with the +
and - buttons.
3.
Set control cam 5 (white) so that the limit switch is actu
-
ated.
4.
Tighten fastening screw A.
5.
Screw B can be used to carry out fine tuning.
6.
Move the door to the desired OPEN position with the +
and - buttons.
7.
Set control cam 2 (green) so that the limit switch is actu
-
ated.
8.
Tighten fastening screw A.
9.
Safety limit switches 3 and 4 (red) must be set so that
they are triggered as soon as the control limit switches are
crossed.
10.
After the trial run, check that the fastening screws are cor
-
rectly tightened.
11.
Auxiliary limit switches 1 and 6 have a potential-free
changeover contact
Limit switches
Содержание FS 345
Страница 1: ...Operating Instructions for FS 345 with FS 101 and CS 300 FS GB FS 345 Door Controls Rev A 0 0 1...
Страница 7: ...GB FS 345 Door Controls Rev A 0 0 7 FS 101 CS 300 FS ready wired FS101 P1 1...
Страница 33: ...GB FS 345 Door Controls Rev A 0 0 33...
Страница 38: ...38 FS 345 Door Controls Rev A 0 0...
Страница 39: ...GB FS 345 Door Controls Rev A 0 0 39...
Страница 40: ...1700009439...