GB
FS 345 Door Controls / Rev.A 0.0 – 19
ADJUSTMENT, INPUT and DIAGNOSIS modes are exited au
-
tomatically 20 seconds after the last button was pressed, and
the control then goes into AUTOMATIC mode.
Operating mode 1: AUTOMATIC
The door system is operated in AUTOMATIC operating mode.
Display:
− Displays the action being carried out
− Displays any errors
If the “PRESS/REL" parameter is set to MOD2 or MOD3 in
the input menu, the display changes from AUTOMATIC to
MANUAL.
Operating mode 2: ADJUSTMENT
In ADJUSTMENT mode, the OPEN/CLOSED end positions are
set.
NOTICE
Malfunctions can occur as a result of incorrect
operation of the control!
In ADJUSTMENT mode, the door will not stop automatically
when it reaches the travel limit position if electronic end
positions (AWG) are used.
The door can be damaged if driven beyond the end posi-
tion.
Fine adjustments can be made in the INPUT operating mode.
Display:
− Displays the travel limit value
Operating mode 3: INPUT
In the INPUT operating mode, the values of various param
-
eters can be altered.
Display:
− Displays the selected parameter
− Displays the current value or status
Operating mode 4: DIAGNOSIS
In the DIAGNOSIS operating mode, door-specific checks can
be queried.
Display:
− Displays the monitored function
− Displays the status of the function
Содержание FS 345
Страница 1: ...Operating Instructions for FS 345 with FS 101 and CS 300 FS GB FS 345 Door Controls Rev A 0 0 1...
Страница 7: ...GB FS 345 Door Controls Rev A 0 0 7 FS 101 CS 300 FS ready wired FS101 P1 1...
Страница 33: ...GB FS 345 Door Controls Rev A 0 0 33...
Страница 38: ...38 FS 345 Door Controls Rev A 0 0...
Страница 39: ...GB FS 345 Door Controls Rev A 0 0 39...
Страница 40: ...1700009439...