GB
FS 345 Door Controls / Rev.A 0.0 – 15
5.13
Connection example for fire alarm con
-
tact
Terminal strip X06
(potential-free continuous contact as normally closed contact)
2
1
X06/FS101
Dip 2 = OFF
1
2
3
4
ON
OFF
5
6
2
X10/FS101
+
-
1
Terminal strip X06
(potential-free continuous contact as normally open contact)
Dip 2 = ON
1
2
3
4
ON
OFF
5
6
2
1
X06/FS101
2
X10/FS101
+
-
1
5.14 Messages
Terminal strip X07
K10 operation / error relay
X07/FS101
In normal operation contact closed, opens in the event of an
error.
Rechargeable battery fault / mains power failure: switches if
the battery is defective or if the battery voltage is less than
19V.
Fire alarm contact
Supply voltage
24 V DC, max. 50 mA
Fire alarm contact
Supply voltage
24 V DC, max. 50 mA
Terminal strip X08
K11 emergency closing relay
X08/FS101
Potential-free switching contact for emergency operation is
active. Switches in the event of emergency closing (contact
closed).
Terminal block X4
K06 operator command relay
X04/FS101
Potential-free switching contact for CLOSE or OPEN command
depending on DIP switches 1 and 3.
(See 12 and 13.1 for wiring and function)
Terminal strip X09
K12 closing edge safety edge (SKS) relay
X09/FS101
Potential-free switching contact, displays status of CESD (SKS)
Содержание FS 345
Страница 1: ...Operating Instructions for FS 345 with FS 101 and CS 300 FS GB FS 345 Door Controls Rev A 0 0 1...
Страница 7: ...GB FS 345 Door Controls Rev A 0 0 7 FS 101 CS 300 FS ready wired FS101 P1 1...
Страница 33: ...GB FS 345 Door Controls Rev A 0 0 33...
Страница 38: ...38 FS 345 Door Controls Rev A 0 0...
Страница 39: ...GB FS 345 Door Controls Rev A 0 0 39...
Страница 40: ...1700009439...