EN
Door Control AS 210 B / Rev.A 2.0 – 7
5.4 Connection arrangement for command
and safety devices
Command and safety devices can be connected via terminals
X3 and X9.
Terminal block X3
- STOP button
- OPEN button
- CLOSE button
- Closing edge safety device (CES)
9
24 V DC max. 150 mA
- Impulse input / radio
9
- Photocell barrier
9
Terminal block X9
- Potential-free connection for red
traffic light or yard light
9
9
Only in connection with an ZM SKS B plug-in circuit card
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
1
2
5 6 7 8
U
V
W
4
5
6
5
4
3
2
1
4
1
2
5.3 Connection arrangement for limit
switches (terminals X5 and X2)
Terminal block X5
Terminal block X2
1
Limit switch OPEN
2
Limit switch CLOSE
4
Pre-limit switch CLOSE (after activation the door does not
reverse)
5
Thermal overload protection for motor
6
Emergency operation (normally closed contact)
7
Safety limit switch CLOSE
8
Safety limit switch OPEN