mFi Mason-Lite MGFPST-43A Скачать руководство пользователя страница 8

6

GUIDELINES FOR USE

As a prowd owner of your Mason-Lite Fireplace, it is imperative 

you familiarize yourself with the information contained in this 

manual, which includes:

• Strict requirements for assembly.

• Detailed instructions for installation.

• Cautionary guidelines for use.

• On-going maintenance instructions.

It  is  the  responsibility  of  the  distributor,  subcontractor  and/

or  the  general  contractor  –  whoever  assumes  the  liability  for 

installation  of  this  product  –  to  see  to  it  that  the  work  is  in 

complete compliance with the guidelines and instructions in this 

manual. Note that the general contractor is the party accountable 

for  seeing  that  adequate  clearances  are  provided  from  all 

firebox surfaces per specifications in this manual. 

 

DO  NOT  USE  A  FIREPLACE  INSERT  OR  OTHER 

PRODUCTS  NOT  SPECIFIED  FOR  USE  WITH  THIS 

FIREPLACE.

The Mason-Lite Fireplace is designed for use only 

with the supplied gas burner system.

DO NOT USE OR STORE GASOLINE OR OTHER FLAMMABLE 

LIQUIDS OR GASES IN OR NEAR THE FIREPLACE!

ATTENTION:

  A  fire  or  an  explosion  could  occur,  causing 

property damage, injury or loss of life if you do not follow the

information in this manual!

NOTE:

 THIS MANUAL MUST BE REPRODUCED ONLY IN

ITS ENTIRETY.

Before Beginning the Installation

Read  these  instructions  carefully  before  beginning  the 

installation  of  this  fireplace.  This  fireplace  is  intended  for 

use  with  a ANSI  Z21.60  Decorative  Gas  Log,  make  sure  all 

components of the Log set are complete before beginning the 

installation into this Enclosure.

Statement of Intended Use:

The  Mason-Lite  Masonry  Fireplace  is  a  modular  refractory 

masonry  unit  designed  for  field  assembly.  The  firebox  is 

constructed using pre-cast, interlocking refractory blocks.

The  blocks  are  then  secured  to  each  other  using  Mortar. 

The system includes all parts necessary for the assembly of a 

complete masonry fireplace. In addition to the basic enclosure, 

a  standard  1-1/8”  thick,  high  temperature  refractory  brick  is 

required to line the interior of the firebox.

These  fireplaces  are  not  intended  to  serve  as  a  primary 

heat source, rather, the fireplace was expressly created as a 

supplemental source of heat. The unit is designed for use with 
burner supplied, Model No.: 

GML-2-39/44(P)A

.

WARNING:

Any application other than the “Intended Use” as stated above 

is in violation of the manufacturer’s instructions and is hereby 

prohibited.  Such  violation  may  cause  immediate  hazard, 

property damage or loss of life and will void all liabilities to the 

manufacturer and will void all warranties explicit or implied.

Introduction

We  extend  a  warm  welcome  from  all  of  us  at  Masonry 

Fireplace  Industries,  LLC.  (MFI),  proud  manufacturers  of 

Mason-Lite Fireplaces. Thank you for choosing MFI.

You may have thought long and hard before you chose the 

fireplace  which  would  grace  your  home.  Rest  assured  that 

every component of the Fireplace has been tested to ensure 

long-term durability.

Product Overview

Mason-Lite  Fireplaces  are  designed  as  factory-built  blocks 

to be assembled on-site. These fireplaces may be installed on 

either combustible or non-combustible floors.

The Main Components of the Mason-Lite Fireplace are:

• 

MASON-LITE Firebox and Smoke Dome

• 

Combustible or Non-Combustible Floor support substructure

• 

Raised Platforms

• 

Mantel clearances

• 

12” B-vent or UL103-12” class A listed chimney system.

Important:

  Follow  the  chimney  pipe  manufacturer’s  instruc

-

tions  on  the  installation  of  their  specific  flue  system.  Careful 

step-by-step instructions for each phase of the installation pro

-

cedure  will  be  given  for  the  Mason-Lite  conventional  radiant 

heat fireplaces. Those instructions generally fall into the follow

-

ing categories: 

• 

Spacing and clearance to combustible materials. 

• 

Familiarity of installation for all components.

• 

The strength of the floor on which it rests.

• 

Chimney system measurements.

• 

Choice  of  materials  and  craftsmanship  in  fireplace  and 

hearth finishing. 

 

 

 

 

Note that each of these topics will be covered in detail and that 

the installer is expected to understand each phase completely 

before going on to subsequent instructions.

Attention

: Be advised that all the illustrations in this manual 

are for general reference only. Do not scale drawings. Actual 

design elements will vary from case to case. Pay attention to 

specified minimum clearances to combustibles.

Testing and listing for the Mason-Lite Fireplace has been 

undertaken by PFS Inc. (Report No. 08-154) to UL 127.

Attention

: You may need a residential building permit to install 

a Mason-Lite Fireplace. Consult local jurisdictions before you 

get started

!

Installing The Gas Fireplace

Содержание Mason-Lite MGFPST-43A

Страница 1: ...requirements of the ANSI Z21 50 standard Solid fuels shall not be burned in this fireplace This appliance must be vented vertically through the roof This appliance is not for installation in manufactu...

Страница 2: ...This page has been left intentionally blank...

Страница 3: ...20 500 mm HEARTH EXTENSION BEYOND SIDES 12 300 mm INSULATION FROM FIREBOX 0 0 mm The installation including provisions for combustion ventilation air and required minimum permanent vent opening must...

Страница 4: ...NT 2 8 LOWER DOME FRONT 2 9 LOWER DOME SIDE 2 10 UPPER DOME FRONT 2 11 UPPER DOME SIDE 2 12 DOME TOP FOR 12 B VENT 1 13 INSULATION BLANKET NOT INCLUDED 14 12 VENT PLATE ASSEMBLY NOT INCLUDED 15 3 REBA...

Страница 5: ...log 30 2 11 MFP 214 Burner Grate Brackets 2 2 Before beginning installation be sure the burner system is complete by comparing its contents with this Parts List Parts may differ depending upon the siz...

Страница 6: ...lt in property damage or personal injury 2 3 8 SPILL SWITCH BAFFLE 43 1 4 53 29 5 8 62 1 8 A A GAS INLET 10 1 4 9 3 4 4 1 4 CHIMNEY OR UL 103 12 ID CLASS A SECTION A A CONNECT TO A 12 B VENT B 38 1 4...

Страница 7: ...he gas fireplace and its required individual shut off valve must be disconnected from the gas supply piping system while performing any tests of the piping system at pressures in excess of psig The ga...

Страница 8: ...plied Model No GML 2 39 44 P A WARNING Any application other than the Intended Use as stated above is in violation of the manufacturer s instructions and is hereby prohibited Such violation may cause...

Страница 9: ...radiant heat is maintained to safe limits Combustible Floor Clearances MGFPST43 Mason Lite Fireplaces have been designed with zero clearance to combustible floors Mason Lite Fireplace Chimney System...

Страница 10: ...Figure 11 for support of anchor rods by the steel support frames For fireplace support foundations installed on concrete refer to Appendix I and II pages 20 21 for specific instructions Rebar locatio...

Страница 11: ...is the task and responsibility of the general contractor installer to see that the proper reinforcement for weight loads are made by a licensed design professional prior to the fireplace installation...

Страница 12: ...quately affix all the fireplace components The mortar is premixed and dry and is to be used to adhere all the fireplace components Be sure to use clean water and work it up into a mixture that is past...

Страница 13: ...e bottle brush prior to placing the epoxy This will ensure a sufficient bond to the concrete Figure 12 Note A DEPUTY INSPECTOR MAY ME REQUIRED FOR THE EPOXY DOWELS PROCESS CHECK WITH YOUR LOCAL BUILDI...

Страница 14: ...till wet 7 Set the remaining lintel as shown in Figure 16 Figure 16 Lintel Lower Dome Side 8 Now you are ready to start the smoke dome assembly Take the lower side dome positioned so that the beveled...

Страница 15: ...the framework to house the chimney system Now that you have completed the smoke dome assembly all the components should stack up for a smooth transition into the flue components Setting the smoke dom...

Страница 16: ...he finished firebrick floor of the fireplace so that it is at least 11 eleven inches above the combustible floor system Disclaimer Masonry Fireplace Industries wishes to express that as the manufactur...

Страница 17: ...hazard MFI cannot be responsible for the make up of material on the exterior of the fireplace you have chosen nor can MFI be held responsible for the materials in a room that may be responding negativ...

Страница 18: ...e sections of vertical pipe that are more than 10 ten feet measuring between elbows you must insert at midpoint a chimney stabilizer When installing the stabilizer pull out the support straps with a g...

Страница 19: ...n 10 feet the top of the chimney still needs to be at least 2 feet above a point measured from a distance of 10 feet horizontally along the roof Though there are many configurations in meeting these r...

Страница 20: ...ht side of the baffle with the sheet metal screws so that the edges are flush with the firebrick Important This baffle assembly and only this the supplied assembly with spill switch must be properly i...

Страница 21: ...and all flames main burner and pilot will go out see important note below OPERATING THE BURNER USING THE REMOTE Move the wall switch to the REMOTE position and follow the instructions included in the...

Страница 22: ...nd chimney system must be completely dry This means that the unit must stand without any firing for a minimum of 28 days Only after that period of time can a first lighting take place Do not let the f...

Страница 23: ...done twice a year In colder climates cleaning should be done more often Always allow the fireplace to completely cool before you work on it which means of course shutting off all gas and electrical c...

Страница 24: ...lts a Check with a millivolt meter Should be 250 millivolts or more b Pilot flame making a blowing sound b Pilot needs adjusting see Checking and Adjusting the Pilot on page 22 c Generator wire leads...

Страница 25: ...ncrete slab The concrete strength and durability shall comply with Sections 1903 1904 and 1905 of the International Building Code IBC TABLE R402 2 MINIMUM SPECIFIED COMPRESSIVE STRENGTH OF CONCRETE MI...

Страница 26: ...ly b Lines defining areas are approximate only Local conditions may be more or less severe than indicated by region classification A severe classification is where weather conditions result in signifi...

Страница 27: ...liate thereof liable in any respect for any injury or damage to the building or structure in which the fireplace has been installed or to the persons or property therein arising out of the use misuse...