mFi Mason-Lite MGFPST-43A Скачать руководство пользователя страница 3

1

CONTENTS

Below is a sample picture of the rating plate that is located inside the lower dome side of your fireplace. Serial number and date 

code should be stamped on the plate where required.

NG

LP

7. HOLES: 4X Ø 0.14” THRU

6. CLEAR BOXES NEXT TO MODEL NUMBERS ARE TO BE STAMPED DURING MANUFACTURE OF FIREPLACE.

5. LARGE TEXT TO BOLD UPPERCASE ARIAL, 10 PT. MIN. (WHERE SHOWN).

4. SMALLEST TEXT TO BE ARIAL, 8 PT. MIN (WHERE SHOWN).

3. ALL TEXT AND GRAPHICS TO BE BLACK ON A CONTRASTING, CLEAR ALUMINUM BACKGROUND.

2. FINISH: CLEAR, PROTECTIVE COATING AT RATED TEMPERATURE IN NOTE 1.

1. MATERIAL:  CLASS IIIA , .024 THICK ALUMINUM RATED AT 302°F (150°C).

NOTES

: (UNLESS OTHERWISE SPECIFIED)

DESCRIPTION:   LABEL, RATING, MGFPST43

P/N: MFP588

REV: B

DATE: 02/16/2015

LAST MODIFIED BY: CB

Doc File Name: MFP588B_RATING PLATE, MGFPST43

PFS

®

US

4.25”

4.00”

6.5”

6.25”

.12”

DATE OF MFG.

SERIAL No.

This appliance is not for installation in manufactured or mobile homes.

    MFP588 rev

.B

GAS 

TYPE:

FOR MANTEL CLEARANCES 

CONSULT OWNER’S MANUAL

DO NOT REMOVE THIS LABEL

See MFI’s installation and operating instructions for this 

model. Contact local building officials about restrictions 

and  installation specifications in your area.

     THIS FIREPLACE IS DESIGNED 

FOR USE ONLY WITH THE ANSI 

Z21.50 DECORATIVE GAS LOGS 

AND BURNER TESTED AND 

APPROVED FOR THIS FIREPLACE.

Consult instructions included with this 

firebox for further information.

!

 

      

 

WARNING:

Use only approved, listed chimneys

12” B-Type Vent and DM-12-12” system, 

UL 103 chimney or a 12” class A 

chimney if preferred.

Chimney Heights:

Max.: 40 ft.

Min.: 14 ft. (17 ft. with 1 or 2 offset 

sections maximum)

IMPORTANT: Refer to pipe 

manufacturer’s instructions.

       

WARNING:

THIS FIREPLACE HAS  BEEN TESTED 

FOR USE ONLY WITH APPROVED  

GLASS DOORS. TO REDUCE THE 

RISK OF FIRE OR INJURY, CONSULT 

OWNER’S MANUAL.

THIS APPLIANCE NEEDS FRESH AIR FOR SAFE OPERATION AND MUST BE INSTALLED 

SO THERE ARE PROVISIONS FOR ADEQUATE COMBUSTION AND VENTILATION AIR.

!

WARNING:

  THIS FIREPLACE IS NOT INTENDED FOR BURNING SOLID FUELS.

!

WARNING:

  

This gas appliance must not be connected to a chimney fuel servicing a solid fuel burning appliance.

!

FIREPLACE CLEARANCES TO COMBUSTIBLES:

UNIT FRONT, SIDES, REAR...............................

0” (0 mm)

COMBUSTIBLE FLOOR......................................

0” (0 mm)

COMB. SHEATHING ABOVE OPENING TOP.....

8”

 (200 mm)

SHEATHING OR TRIM TO OPENING SIDES....12“ (300 mm)

OPENING TO SIDE WALL..................................20

 (500 mm)

HEARTH EXTENSION BEYOND SIDES............12“ (300 mm)

INSULATION FROM FIREBOX............................

0”  

(0 mm)

The installation, including provisions for combustion, ventilation air, and required minimum permanent vent opening,

must conform with the National Fuel Gas Code (ANSI Z223.1/NFPA 54) and applicable local building codes.

MODEL

  No.:

MGFPST-43

MFI

Masonry

Fireplace

Industries, LLC

6391 Jurupa Ave.

Riverside, CA 92514

LARR No. 25924

Tested & Listed By

Report No.

 08-154

Fireplace Parts List

 .......................................................... 3

Fireplace Overall Dimensions

.......................................... 4

Fireplace Framing Dimensions

 ........................................ 4

Burner and Logs Parts List

 .............................................. 5

Important Pre-installation Information

.............................. 6

Installing the Gas Fireplace

 ............................................. 7

Clearance to Combustibles

 ............................................. 8

Supporting Floor Systems ............................................... 9

MASON-LITE Weight Determination

 ............................... 10

Mason-Lite™ Component for combustible floors

 ............ 11

Field Assembly Procedures

 ............................................. 11

Fireplace Assembly Procedures

 ...................................... 12

Vent Plate

 ........................................................................ 13

Firestop Radiation Shield ................................................ 14

Mason-Lite™ Firebrick Liners

.......................................... 14

Fireplace Finishes & Combustible Trim Clearances

 ........ 15

Mantle and Mantle Shelf Clearances

............................... 16

Installing Outside Combustion (make-up) Air

 .................. 16

Adding a Gas Pipe

........................................................... 16

Adding Electrical Connection

........................................... 16

MASON-LITE Chimney Systems:

.................................... 16

Installing Chimney System .............................................. 17

Fireplace Door Accessory

................................................ 17

Customer Service & Parts Replacement

 ......................... 17

Appendix I........................................................................ 18

Installing the Spill Switch and Baffl e Assembly

 .............. 19

Installing Spill Switch and Baffl e assembly

 ..................... 19

Owner’s Operation & Precautions

 ................................... 19

Installing the Gas Burner  ................................................ 20

Attaching the Burner and the Grate 

 ................................ 20

Checking and Adjusting the Pilot (if neccessary) 

............ 20

Heat shield placement 

 .................................................... 20

Adjusting Air Mixers 

 ........................................................ 20

Placing the Decorative Lava Rock 

.................................. 20

Placing the Logs 

 ............................................................. 21

Log Placement 

................................................................ 21

Lighting and Operating Instructions 

 ................................ 22

Lighting the Pilot 

 ............................................................. 22

Lighting and Extinguishing the Burner System 

 ............... 22

Maintaining the Pilot 

 ....................................................... 22

Cleaning and Checking 

 .................................................. 22

Safety Pilot System 

 ........................................................ 22

Maintenance and Service 

 ............................................... 23

Troubleshooting  .............................................................. 23

Maintenance 

 ................................................................... 23

Service 

............................................................................ 23

Flame Appearance 

 ......................................................... 23

Troubleshooting  .............................................................. 23

Содержание Mason-Lite MGFPST-43A

Страница 1: ...requirements of the ANSI Z21 50 standard Solid fuels shall not be burned in this fireplace This appliance must be vented vertically through the roof This appliance is not for installation in manufactu...

Страница 2: ...This page has been left intentionally blank...

Страница 3: ...20 500 mm HEARTH EXTENSION BEYOND SIDES 12 300 mm INSULATION FROM FIREBOX 0 0 mm The installation including provisions for combustion ventilation air and required minimum permanent vent opening must...

Страница 4: ...NT 2 8 LOWER DOME FRONT 2 9 LOWER DOME SIDE 2 10 UPPER DOME FRONT 2 11 UPPER DOME SIDE 2 12 DOME TOP FOR 12 B VENT 1 13 INSULATION BLANKET NOT INCLUDED 14 12 VENT PLATE ASSEMBLY NOT INCLUDED 15 3 REBA...

Страница 5: ...log 30 2 11 MFP 214 Burner Grate Brackets 2 2 Before beginning installation be sure the burner system is complete by comparing its contents with this Parts List Parts may differ depending upon the siz...

Страница 6: ...lt in property damage or personal injury 2 3 8 SPILL SWITCH BAFFLE 43 1 4 53 29 5 8 62 1 8 A A GAS INLET 10 1 4 9 3 4 4 1 4 CHIMNEY OR UL 103 12 ID CLASS A SECTION A A CONNECT TO A 12 B VENT B 38 1 4...

Страница 7: ...he gas fireplace and its required individual shut off valve must be disconnected from the gas supply piping system while performing any tests of the piping system at pressures in excess of psig The ga...

Страница 8: ...plied Model No GML 2 39 44 P A WARNING Any application other than the Intended Use as stated above is in violation of the manufacturer s instructions and is hereby prohibited Such violation may cause...

Страница 9: ...radiant heat is maintained to safe limits Combustible Floor Clearances MGFPST43 Mason Lite Fireplaces have been designed with zero clearance to combustible floors Mason Lite Fireplace Chimney System...

Страница 10: ...Figure 11 for support of anchor rods by the steel support frames For fireplace support foundations installed on concrete refer to Appendix I and II pages 20 21 for specific instructions Rebar locatio...

Страница 11: ...is the task and responsibility of the general contractor installer to see that the proper reinforcement for weight loads are made by a licensed design professional prior to the fireplace installation...

Страница 12: ...quately affix all the fireplace components The mortar is premixed and dry and is to be used to adhere all the fireplace components Be sure to use clean water and work it up into a mixture that is past...

Страница 13: ...e bottle brush prior to placing the epoxy This will ensure a sufficient bond to the concrete Figure 12 Note A DEPUTY INSPECTOR MAY ME REQUIRED FOR THE EPOXY DOWELS PROCESS CHECK WITH YOUR LOCAL BUILDI...

Страница 14: ...till wet 7 Set the remaining lintel as shown in Figure 16 Figure 16 Lintel Lower Dome Side 8 Now you are ready to start the smoke dome assembly Take the lower side dome positioned so that the beveled...

Страница 15: ...the framework to house the chimney system Now that you have completed the smoke dome assembly all the components should stack up for a smooth transition into the flue components Setting the smoke dom...

Страница 16: ...he finished firebrick floor of the fireplace so that it is at least 11 eleven inches above the combustible floor system Disclaimer Masonry Fireplace Industries wishes to express that as the manufactur...

Страница 17: ...hazard MFI cannot be responsible for the make up of material on the exterior of the fireplace you have chosen nor can MFI be held responsible for the materials in a room that may be responding negativ...

Страница 18: ...e sections of vertical pipe that are more than 10 ten feet measuring between elbows you must insert at midpoint a chimney stabilizer When installing the stabilizer pull out the support straps with a g...

Страница 19: ...n 10 feet the top of the chimney still needs to be at least 2 feet above a point measured from a distance of 10 feet horizontally along the roof Though there are many configurations in meeting these r...

Страница 20: ...ht side of the baffle with the sheet metal screws so that the edges are flush with the firebrick Important This baffle assembly and only this the supplied assembly with spill switch must be properly i...

Страница 21: ...and all flames main burner and pilot will go out see important note below OPERATING THE BURNER USING THE REMOTE Move the wall switch to the REMOTE position and follow the instructions included in the...

Страница 22: ...nd chimney system must be completely dry This means that the unit must stand without any firing for a minimum of 28 days Only after that period of time can a first lighting take place Do not let the f...

Страница 23: ...done twice a year In colder climates cleaning should be done more often Always allow the fireplace to completely cool before you work on it which means of course shutting off all gas and electrical c...

Страница 24: ...lts a Check with a millivolt meter Should be 250 millivolts or more b Pilot flame making a blowing sound b Pilot needs adjusting see Checking and Adjusting the Pilot on page 22 c Generator wire leads...

Страница 25: ...ncrete slab The concrete strength and durability shall comply with Sections 1903 1904 and 1905 of the International Building Code IBC TABLE R402 2 MINIMUM SPECIFIED COMPRESSIVE STRENGTH OF CONCRETE MI...

Страница 26: ...ly b Lines defining areas are approximate only Local conditions may be more or less severe than indicated by region classification A severe classification is where weather conditions result in signifi...

Страница 27: ...liate thereof liable in any respect for any injury or damage to the building or structure in which the fireplace has been installed or to the persons or property therein arising out of the use misuse...